FP
Σ
13.6 Table of Special Data Registers
13 - 31
(A: Available, N/A: Not available)
Address Name
Description
Reading Writing
DT90044
High-
speed
counter
For
ch0
The elapsed value (32-bit data) for the high-speed counter is
stored here. The value can be read and written by executing
F1 (DMV)
instruction
A
A
DT90045
counter
elapsed
value
F1 (DMV)
instruction.
DT90046
High-
speed
counter
target
For
ch0
The target value (32-bit data) of the high-speed counter
specified by the high-speed counter instruction is stored
here.
Target values have been preset for the various instructions
A
N/A
DT90047
target
value
Target values have been preset for the various instructions,
to be used when the high-speed counter related instruction
“
F166, F167, F171, F175
or
F176
” is executed.The value can
be read by executing
F1 (DMV)
instruction.
DT90048
High-
speed
counter
For
ch1
The elapsed value (32-bit data) for the high-speed counter is
stored here.The value can be read and written by executing
F1 (DMV)
instruction.
A
A
DT90049
counter
elapsed
value
area
F1 (DMV)
instruction.
DT90050
High-
speed
counter
target
For
ch1
The target value (32-bit data) of the high-speed counter
specified by the high-speed counter instruction is stored
here.
Target values have been preset for the various
A
N/A
DT90051
target
value
area
Target values have been preset for the various
instructions, to be used when the high-speed counter related
instruction “
F166
or
F167
” is executed.The value can be read
by executing
F1 (DMV)
instruction.
DT90052
High-speed
counter and
pulse output
control flag
A value can be written with
F0 (MV)
instruction to reset the
high-speed counter, disable counting, continue or clear
high-speed counter instruction.
Software reset
0: No/1: Yes
Home near input
0: Invalid/1: Valid
Channel setting
0 to 3: CH0 to CH3
Hardware reset
0: Enable/1: Disable
Count
0: Enable/1: Disable
15
0
High - speed counter
instruction
0: Continue/1: Clear
Pulse output
0: Continue/1: Stop
11
2
3
4
Control code setting
N/A
A
Содержание FP Series
Страница 15: ...FP Functions and Restrictions of the Unit 1 2...
Страница 25: ...FP Specifications and Functions of Control Unit 2 2...
Страница 37: ...FP Expansion 3 2...
Страница 44: ...Chapter 4 I O Allocation 4 1 I O Allocation 4 3...
Страница 45: ...FP I O Allocation 4 2...
Страница 51: ...FP Installation and Wiring 5 2...
Страница 77: ...FP High speed Counter and Pulse Output Functions 6 2...
Страница 133: ...FP High speed Counter and Pulse Output Functions 6 58...
Страница 135: ...FP Communication Cassette 7 2...
Страница 147: ...FP Communication Function 1 Computer Link 8 2...
Страница 169: ...FP Communication Function 2 General purpose Serial Communication 9 2...
Страница 205: ...FP Communication Function 2 General purpose Serial Communication 9 38...
Страница 207: ...FP Communication Function 3 PLC Link Function 10 2...
Страница 232: ...Chapter 11 Other Functions 11 1 Analog Potentiometer 11 3 11 2 Clock Calendar Function 11 4...
Страница 233: ...FP Other Functions 11 2...
Страница 238: ...Chapter 12 Self Diagnostic and Troubleshooting 12 1 Self Diagnostic Function 12 3 12 2 Troubleshooting 12 5...
Страница 239: ...FP Self Diagnostic and Troubleshooting 12 2...
Страница 249: ...FP Self Diagnostic and Troubleshooting 12 12...
Страница 251: ...FP Specifications 13 2...
Страница 323: ...Index FP I 4...
Страница 325: ...FP Record of changes R 2...