Specifications
13 - 38
(A: Available, N/A: Not available)
Address Name
Description
Reading Writing
DT90170
MEWNET-W0
PLC link status
Duplicated destination for PLC inter-link address A
N/A
DT90171
PLC link status
Counts how many times a token is lost.
DT90172
Counts how many times two or more tokens are
detected.
DT90173
Counts how many times a signal is lost.
DT90174
No. of times undefined commands have been
received
DT90175
No. of times sum check errors have occurred
during reception
DT90176
No. of times format errors have occurred in re-
ceived data
DT90177
No. of times transmission errors have occurred
DT90178
No. of times procedural errors have occurred
DT90179
No. of times overlapping parent units have occurred
DT90180
to
DT90189
Not used
N/A
N/A
DT90190
High-speed counter control
flag monitor for ch0
0
This monitors the data specified in DT90052.
1
2
3
4
A
N/A
DT90191
High-speed counter control
flag monitor for ch1
DT90192
High-speed counter control
flag monitor for ch2
Home near input
High- speed counter instruction
Pulse output
H d
0: Invalid/1: Valid
0: Continue/1: Clear
0: Continue/1: Stop
E bl / Di bl
DT90193
High-speed counter control
flag monitor for ch3
Hardware reset
Count
Software reset
0: Enable/1: Disable
0: Enable/1: Disable
0: No/1: Yes
DT90194
to
DT90199
Not used
N/A
N/A
DT90200
High-speed
counter elapsed
For ch2
The elapsed value (32-bit data) for the high-speed
counter is stored here. The value can be read and
A
A
DT90201
counter elapsed
value
counter is stored here. The value can be read and
written by executing
F1 (DMV)
instruction.
DT90202
High-speed
counter target
value
For ch2
The target value (32-bit data) of the high-speed
counter specified by the high-speed counter
instruction is stored here.
Target values have been preset for the various
A
N/A
DT90203
Target values have been preset for the various
instructions, to be used when the high-speed
counter related instruction “
F166, F167, F171 , F175
or
F176
” is executed. The value can be read by
executing
F1 (DMV)
instruction.
DT90204
High-speed
counter elapsed
For ch3
The elapsed value (32-bit data) for the high-speed
counter is stored here The value can be read and
A
A
DT90205
counter elapsed
value
counter is stored here.The value can be read and
written by executing
F1 (DMV)
instruction.
Содержание FP Series
Страница 15: ...FP Functions and Restrictions of the Unit 1 2...
Страница 25: ...FP Specifications and Functions of Control Unit 2 2...
Страница 37: ...FP Expansion 3 2...
Страница 44: ...Chapter 4 I O Allocation 4 1 I O Allocation 4 3...
Страница 45: ...FP I O Allocation 4 2...
Страница 51: ...FP Installation and Wiring 5 2...
Страница 77: ...FP High speed Counter and Pulse Output Functions 6 2...
Страница 133: ...FP High speed Counter and Pulse Output Functions 6 58...
Страница 135: ...FP Communication Cassette 7 2...
Страница 147: ...FP Communication Function 1 Computer Link 8 2...
Страница 169: ...FP Communication Function 2 General purpose Serial Communication 9 2...
Страница 205: ...FP Communication Function 2 General purpose Serial Communication 9 38...
Страница 207: ...FP Communication Function 3 PLC Link Function 10 2...
Страница 232: ...Chapter 11 Other Functions 11 1 Analog Potentiometer 11 3 11 2 Clock Calendar Function 11 4...
Страница 233: ...FP Other Functions 11 2...
Страница 238: ...Chapter 12 Self Diagnostic and Troubleshooting 12 1 Self Diagnostic Function 12 3 12 2 Troubleshooting 12 5...
Страница 239: ...FP Self Diagnostic and Troubleshooting 12 2...
Страница 249: ...FP Self Diagnostic and Troubleshooting 12 12...
Страница 251: ...FP Specifications 13 2...
Страница 323: ...Index FP I 4...
Страница 325: ...FP Record of changes R 2...