3.1 Bypass mode
(continued)
X) Sensor FC2 is inactive.
Sensor FC2 activation should be less than 2 seconds,
after that the STR will give an error STR104.
To check if the booklet was transported from the Paper-stop
to the outfeed.
Solenoid M1 is deactivated and the Paper-stop is closing.
XI) Outfeed Sensor FC1 is active.
The time between sensor FC2 and FC1 should be less than 1
second, after that the STR will give an error STR105.
To check if the booklet has arrived at the outfeed correctly.
XII) Sensor FC1 is inactive.
The time when FC1 is activated should be less than 2
seconds, after that the STR will give an error STR106.
To check if the booklet was transported out of the STR
correctly.
The belt propulsion motor (Motor5) stops.
The booklet is transported out of the STR.