© Ernst Nagel GmbH 2S Trimmer Service Manual en.doc Rev.1.0. 20.07.2011
127
Contents
8. NVM Values
(continued)
8.2 Adjusting NVM Values
The following table and figure is for support of this chapter.
The table explains which NVM is coupled to which Motor and what the result is of higher or lower
the NVM value of the concerning Motor.
Use the following table and figure to get a better view by what will happen during adjusting the
NVM values in the next chapters.
Values
NVM
ID
Motor
Position
Min.
Max.
Def.
Use.
0
Counter
Total
Counter
- 0 0 0 0
1 Motor
6
Home Position (See Fig. 8.10)
+ : Smaller Finished size
- : Larger Finished Size
Lower
Right
1800 2050 1990 1990*
2 Motor
7
Infeed Position (See Fig. 8.10)
+ : More Infeed Space
- : Less Infeed Space
Left 400 500 485 485
3 Motor
7
Compress Correction (See Fig. 8.10)
+ : More Compression / Less Trimming
- : Less Compression / More Trimming
Left 900
1100 1000
1000
4 Motor
8
Infeed Position (See Fig. 8.10)
+ : More Infeed Space
- : Less Infeed Space
Right 400 500 485 485
5 Motor
8
Compress Correction (See Fig. 8.10)
+ : More Compression / Less Trimming
- : Less Compression / More Trimming
Right 900
1100 1000
1000
**Recommend to use values < 2000
Fig. 8.10
2
3
Fig. 8.9
1
4
5