© Ernst Nagel GmbH 2S Trimmer Service Manual en.doc Rev.1.0. 20.07.2011
98
Contents
6. Default / basic adjustments
(continued)
6.3 Sensors and Switches
(continued)
6.3.1 Replace Photo Sensors
(continued)
Fig.
6.25
Fig.
6.26
Removal
No. Action
Remarks
1
Open the Top Cover or Remove the Base plate Cover
(See Chap.
4.7
)
2
Disconnect the orange Photo sensor cable.
3
Remove the Photo sensor FC4 or FC7 [
LK89PD8
] inside the Base.
(See Fig. 6.25 & 6.26)
Installation
No. Action
Remarks
1
For installation follow the Removal procedure in reversed order.
FC4
FC7