© Ernst Nagel GmbH 2S Trimmer Service Manual en.doc Rev.1.0. 20.07.2011
134
Contents
9. Maintenance
9.1 Preventive maintenance table
If any of the checkpoints area’s or other parts show indication of wear at any point, replace the parts.
When parts need a new lubrication, clean the surface if necessary before applying a new lubricant.
The STR requires a minimum of 400mm of additional floor space on the back side for installation, operation
and maintenance.
Run the Checkpoints STR at an interval of 250.000 sets.
Symbol key: C = Cleaning,
I = Inspect,
L = Lubricate,
R = Replace,
W = Wipe
Checkpoints area’s STR after 250.000 sets
Checkpoints
NOTE
Paper path
C
Dry Cloth / Brush
Sensors
C
Dry Cloth / Brush
Transport module
I
Inspect
Upper belt (1x)
W
Moister Cloth
Lower belt (3x)
W
Moister Cloth
Trim knives
I
Inspect
Knives (L+R)
I
Inspect
Knife guiding blocks
L / I
Grease
Protection plate knife guidance
L / I
Grease
Knife chains
L
Oil
Knife sprockets
L
Oil
Side Jogger guidance
L
Grease