© Ernst Nagel GmbH 2S Trimmer Service Manual en.doc Rev.1.0. 20.07.2011
117
Contents
6. Default / basic adjustments
(continued)
6.8 Tapping Transformer and blown fuse conditions
(continued)
Removal
No. Action
Remarks
1
Remove Cover Left / Right
See Chap.
4.2
2
Check which symptom the machine shows
3
Remove the blown out Fuse (Transformer [F14/ F15] or Fuse
holder [F12]).
Installation
No. Action
Remarks
1
For installation follow the Removal procedure in reversed order.
Fuse
Rate
Symptom at power on
F12
4AT
STR
no
com
(no
response)
F14
2AT
STR
no
com
(no
response)
F15
16AT Cover
open
indication
F14
F15
F12