GT20 Control Wiring and Programming Manual
Part #C-00140
Rev. 10-7-16
8-34
Double Swinging Doors
CHAPTER 8: DOUBLE SWING DOORS
DN 1183
Master Door Panel:
Opens fi rst; Closes second
Slave Door Panel:
Opens second; Closes fi rst
Master Operator Assembly
Slave Operator Assembly
Figure 8-1
Open, Close sequence Order
Section 8a: Activation Input Connections:
Activation Inputs:
X
(KE) Night Mode
X
(OEO) Exterior Activation Sensor
X
(OEI) Interior Activation Sensor
Connected to the:
X
Master Door Panel
•
Will open the Master door only.
X
Slave Door Panel
•
Will force the Master Door Panel to open first and then the Slave Door Panel second.
Section 8b: Safety Element Connections:
Safety Elements that are connected to their respective GT20 Controls:
X
(SER) Push side door mounted Sensor (for re-opening the door).
X
(SES) Pull side door mounted Sensor (for stopping the door).
Section 8c: EMY-IN Sensor Connections:
An active (EMY-IN) Emergency Input Signal Sensor connected to the:
X
Master Door Panel
•
Will force the Master Door Panel to open first and then the Slave Door Panel second.
X
Slave Door Panel
•
Will force the Slave Door Panel to open first and then the Master Door Panel second.
Section 8d: Electric Lock Connections:
An electric lock, that is connected to the:
X
Master Operator Assembly
•
Locks the Master Door Panel
X
Slave Operator Assembly
•
Locks the Slave Door Panel
Содержание GT20