GT20 Control Wiring and Programming Manual
Part #C-00140
Rev. 10-7-16
10-44
Troubleshooting
Table 10-6
System
No
Description
Cause
Elimination
Checking Time
Reaction
E50 01-99 System Error Unexpected hardware
or software event
Switch the drive unit Off/On
Carry out a Factory Reset,
carry out a Software Update,
inform the manufacturer
Permanent
W or H or F
E51
E52
Table 10-7
Closing Sequence / Interlock Function
No
Description
Cause
Elimination
Checking Time
Reaction
70
xx CAN bus setting CAN address xx
existing twice
Correctly define the role of the
Closing Sequence or the
Interlock Function
Permanent
W
E71 01 CAN connection No CAN
connection
X
Plug in, check or replace the
CAN cable
X
Check if all the CAN participants
are switched on
Permanent
W
Table 10-8
UL Test
No
Description
Cause
Elimination
Checking Time
Reaction
E80 01 Continuous
Routine
Malfunction
--
Permanent
W
02
Power Down then Power Up
F
E81 01 mcu Routine
--
X
Before:
y
Opening Door
y
Closing Door
W
02
Power Down then Power Up
F
E82 01 Dynamic Routine Damping Test
Failed
--
After Power
Down then every
24 hrs when
door is closing
W
02
Power Down then Power Up
F
E83 01 Static Routine
Motor Current
Test Failed
--
After each
closing
movement (in
Closed position)
W
02
Power Down then Power Up
F