Rev. 10-7-16
Part #C-00140
GT20 Control Wiring and Programming Manual
Initial Setup Procedure
6-23
Attention: Upon the first activation of opening the Door OR in the event the Door loses power:
The Door
will fully Open. About half way closing, the door will jerk stop (this is called Motor Damping).
This is an UL Requirement to test the Spring. After Motor Damping the door will fully close
.
Note: Values within the Setup Procedure are Password protected.
1.►Go to the Power/Program Selector Switch. Flip the Power Switch ON.
a. The first Element Press Down will be displayed blinking upside down and right side up.
Press
Down
Press
Down
a. First you have to choose between Europe/USA
Region
EU
Region
EU
Region
USA
2.►Move the Joystick up or down. The Element will stop blinking and be right side up for each
circumstance.
Region
US
3.►Briefly push down on the Joystick. The Value will start to blink on the lower half of the screen.
4.►Move the Joystick to the Right or to the Left to select(1) of the following Values.
Rod
STD-PH
Rod
SLI-PL
Rod
WIN-PH
Rod
DIR-PH
Rod
DIR-PL
Rod
OHC-PH
Rod
OHC-PL
5.►Briefly push down on the Joystick to (OK) selection.
6.►Move the Joystick Down until the Element dAxis is displayed.
dAxis
2.8 in
7.►Briefly push down on the Joystick. The Value will start to blink on the lower half of the screen.
8.►Move the Joystick to the Right or to the Left to select(1) of the following Values: 0cm...25cm
a. dAxis is an approximate Value. The installation may have to be adapted accordingly.
DN 1181
Centerline of Door Pivot
or Hinge
dAxis
Moun ng Plate (op on)
+ —
dAxis
+ —
1 cm = 3/8 inch
2 cm = 3/4 inch
3 cm = 1-3/16 inch
4 cm = 1-1/2 inch
5 cm = 2 inch
6 cm = 2-3/8 inch
Figure 6-2
Set the dAxis