Indoor Unit
Installation
*OEPPSVOJUPVUMJOF
Unit: mm
Step 3: Drill wall hole for connective piping
1.
Determine the location of the wall hole based
CAUTION:
The Bubble level on the mounting
plate can’t be removed. If it is broken, make
sure to clean up the leaking liquid.
Vertical direction
ruler
Horizontal direction ruler
on the position of the mounting plate. Refer
to
Mounting Plate Dimensions.
8BMM
*OEPPS
0VUEPPS
N
N
-
JO
MOUNTING PLATE DIMENSIONS
Different models have different mounting plates.
For the convenience of installation, there are
bubble level, carved dimensions on the
mounting plate. Please install the plate and drill
wall hole according to the information of the
mounting plate. See the figures below.
$PSSFDUPSJFOUBUJPOPG.PVOUJOH1MBUF
2.
Using a 65mm (2.5in) or 90mm (3.54in)
(depending on models) core drill, drill a
hole in the wall. Make sure that the hole
is drilled at a slight downward angle, so
that the outdoor end of the hole is lower
than the indoor end by about 5mm to
7mm (0.2-0.275in). This will ensure proper
water drainage.
3.
Place the protective wall cuff in the hole.
This protects the edges of the hole and
will help seal it when you finish the
installation process.
CAUTION
When drilling the wall hole, make sure
to
avoid wires, plumbing, and other
sensitive components.
NOTE:
When the gas side connective pipe is
16mm (5/8in) or more, the wall hole should
be 90mm (3.54in).
FROM EDGE TO HOLE CENTER:50mm
FROM EDGE TO HOLE CENTER:50mm
FROM EDGE TO HOLE CENTER:95mm
FROM EDGE TO HOLE CENTER:70mm
150
100
100
965
795
50
95
120
570.7
70
1140
50
pipe hole
65
pipe hole
65
pipe hole
65
pipe hole
65
pipe hole
65
50
pipe hole
65
490
425
322
295
370
50
40
40
60
51
100
50
50
50
2
2
2
4
4
4
6
RECOMMAND
LIQUID
GAS
BUBBLE
LEVEL
BUBBLE
LEVEL
mm
inch
150
100
50
2
4
6
RECOMMAND
mm
inch
mm
inch
100
100
50
50
2
2
4
4
LIQUID
GAS
mm
inch
FROM EDGE TO HOLE CENTER:50mm
FROM EDGE TO HOLE CENTER:100mm
150
100
100
100
50
50
50
2
2
2
4
4
4
6
RECOMMAND
LIQUID
GAS
BUBBLE
LEVEL
mm
inch
mm
inch
FROM EDGE TO HOLE CENTER:50mm
FROM EDGE TO HOLE CENTER:100mm
150
100
100
100
50
50
50
2
2
2
4
4
4
6
RECOMMAND
LIQUID
GAS
BUBBLE
LEVEL
mm
inch
mm
inch
FROM
EDGE TO HOLE CENTER:50mm
FROM
EDGE TO HOLE CENTER:100mm
150
100
100
100
50
50
50
2
2
2
4
4
4
6
RECOMMAND
LIQUID
GAS
BUBBLE
LEVEL
mm
inch
mm
inch
BUBBLE
LEVEL
150
100
50
2
4
6
RECOMMAND
mm
inch
100
100
50
50
2
2
4
4
LIQUID
GAS
mm
inch
40
*OEPPSVOJUPVUMJOF
*OEPPSVOJUPVUMJOF
Models 9 / 12
Model 18
Model 24
82
Содержание MUPR-H10X Series
Страница 2: ...ES EN PT DE 3 60 117 174 MUPR H10X FR 231...
Страница 43: ...Manual del Control Remoto Control remoto Especificaciones del Control Remoto 43...
Страница 44: ...Control remoto Informaci n Previa a su Utilizaci n 44...
Страница 48: ...Control remoto 48...
Страница 49: ...Control remoto 49...
Страница 50: ...Control remoto 50...
Страница 52: ...Control remoto 52...
Страница 53: ...Control remoto Funci n Silence 53...
Страница 288: ...www mundoclima com C N POLES 249 P1 08013 BARCELONA 34 93 446 27 80 SAT 34 93 652 53 57 ESPA A SPAIN...