ISOBUS-TC task processing
Configuring the list of connections
10
31302713-02-EN
V5.20170221
65
"Save finished tasks as a file?" parameter
If this parameter is activated, all ISO-XML tasks are saved on the memory device as a text file.
“Validation of the device description” parameter
Optional parameter. Deactivated per default.
Please note that when the parameter is activated, Task-Controller version 3 is supported. If the
parameter is deactivated, Task-Controller version 2 is supported.
Only activate this parameter if you want to ensure that SECTION-Control and ISOBUS-TC only
communicate with AEF-compliant job computers.
Job computers that are not AEF-compliant are not supported by ISOBUS-TC in this case.
Configuring the list of connections
The list of connections indicates the ISOBUS job computers from which the terminal will load the
geometries of the connected implements. This geometry is required in order to calculate the position
of all implement components on the basis of the GPS signal. Only in this way are precise parallel
driving and section switching possible.
The farm equipment must be ordered consecutively from the front to the rear when viewed in the direction of
travel
Tractor job computer icon In this case, it is the
Tractor-ECU application of the terminal.
ISO number for the ISOBUS job computer
There is a connection between "Tractor-ECU"
and "ME_ISO_Sprayer".
- connected implements.
Name of the job computer
Icon for the "ME_ISO_Sprayer " ISOBUS job
computer
Not all of the equipment in the list must be
connected. Job computers which contain no
relevant geometric data can be disconnected.
In the image, the "Tractor" job computer has
been disconnected, as the tractor geometry
should be transferred from the Tractor-ECU
application of the terminal.
- disconnected implements.
If you are not using the ISOBUS-TC application, you can configure the list of connections as follows:
All ISOBUS job computers are connected to the ISOBUS.
10.1.5
10.1.6
10.2
Procedure