3.3 Engine data 16V 4000 M54, EPA Tier 3, IMO Tier II
Explanation
Abbrevia-
tion
Meaning
DL
Ref. value: Continuous power
BL
Ref. value: Fuel stop power
A
Design value
G
Guaranteed value
R
Guideline value
L
Limit value up to which the engine can be operated without change, e.g. of power setting.
N
Not yet defined value
-
Not applicable
X
Applicable
Heat exchanger
engine-mounted
Heat exchanger
remote
Application group
1A
1A
1A
1A
Intake air temperature
°C
25
45
25
45
Raw water inlet temperature
°C
25
32
25
32
Barometric pressure
mbar
1000
1000
1000
1000
Site altitude above sea level
m
100
100
100
100
Power-related data (power ratings are net brake power as per ISO 3046)
Heat exchanger
engine-mounted
Heat exchanger
remote
Rated engine speed
A rpm
1800
1800
1800
1800
Fuel stop power ISO 3046
A kW
1685
1685
1685
1685
General conditions (for maximum power)
Heat exchanger
engine-mounted
Heat exchanger
remote
Intake depression (new filter)
A mbar
15
15
15
15
Intake depression, max.
L
mbar
30
30
30
30
Model related data (basic design)
Heat exchanger
engine-mounted
Heat exchanger
remote
Cylinder arrangement: V angle
Degrees
(°)
90
90
90
90
Bore
mm
170
170
170
170
Stroke
mm
210
210
210
210
Cylinder displacement
Liters
4.77
4.77
4.77
4.77
Total displacement
Liters
76.3
76.3
76.3
76.3
66 | Technical Data | MS150110/00E 2013-10
TIM-ID: 0000045623 - 001