![MTU 12 V 4000 Mx4 Скачать руководство пользователя страница 253](http://html1.mh-extra.com/html/mtu/12-v-4000-mx4/12-v-4000-mx4_operating-instructions-manual_1852652253.webp)
7.21.5 Interface module EIM plug connections – Check
Preconditions
☑
Engine is stopped and starting disabled.
Checking EIM plug connections
1.
Check both Tyco plugs (62-pole) (2) on EIM
for firm seating. Ensure that clips (3) are
engaged.
2.
Check screws (1) of cable clamps on EIM
for firm seating. Ensure that cable clamps
are not faulty.
MS150110/00E 2013-10 | Task Description | 253