461 – LO T-Exhaust EMU
ZKP-Number: 2.8006.653
Limit value 1
Cause
Corrective action
EMU exhaust gas temperature
value too low.
1. Check wiring.
2. Contact Service.
462 – HI T-Coolant EMU
ZKP-Number: 2.8006.654
Limit value 1
Cause
Corrective action
EMU coolant temperature value
too high / low.
u
Check configuration with DiaSys.
464 – SD P-AUX 1
ZKP-Number: 1.8004.589
Cause
Corrective action
Analog input signal for Aux 1
pressure faulty; short circuit or
wire break.
u
Check pressure transmitter and wiring, replace as necessary.
Fault is rectified following engine restart.
467 – AL L2 T-Aux 1
ZKP-Number: 2.0130.922
Limit value 2
Cause
Corrective action
Temperature signal of Aux 1 has
exceeded / not attained limit
value 2, depending on
configuration.
u
Determine cause of limit value violation and rectify fault.
468 – SD T-AUX 1
ZKP-Number: 1.8004.579
Signal error, temperature Aux 1
Yellow alarm; warning
Cause
Corrective action
Analog input for Aux 2
temperature faulty.
u
-
MS150110/00E 2013-10 | Troubleshooting | 153