![MTU 12 V 4000 Mx4 Скачать руководство пользователя страница 147](http://html1.mh-extra.com/html/mtu/12-v-4000-mx4/12-v-4000-mx4_operating-instructions-manual_1852652147.webp)
408 – AL Open Load Emerg. Stop Input ESI
ZKP-Number: 2.8006.633
Line disruption at input for emergency stop
Yellow alarm; warning
Cause
Corrective action
Wiring faulty or no resistance
over switch.
1. Check wiring (→ Page 248).
2. Check target device input.
3. Contact Service.
410 – LO U-PDU
ZKP-Number: 2.0141.921
Injector voltage too low (limit value 1)
Yellow alarm; warning
Cause
Corrective action
Wiring damage or faulty current
supply.
1. Check wiring (→ Page 248).
2. Check supply.
3. Contact Service.
411 – LOLO U-PDU
ZKP-Number: 2.0141.922
Injector voltage too low (limit value 2)
Red alarm; engine shutdown
Cause
Corrective action
Wiring damage or faulty current
supply.
1. Check wiring (→ Page 248).
2. Check supply.
3. Acknowledge alarm.
4. Contact Service.
412 – HI U-PDU
ZKP-Number: 2.0141.931
Injector voltage too high (limit value 1)
Yellow alarm; warning
Cause
Corrective action
Wiring damage or faulty current
supply.
1. Check wiring (→ Page 248).
2. Check supply.
3. Contact Service.
MS150110/00E 2013-10 | Troubleshooting | 147