![MTU 12 V 4000 Mx4 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/mtu/12-v-4000-mx4/12-v-4000-mx4_operating-instructions-manual_1852652029.webp)
HP connections
1 Jacket pipe
2 HP fuel line
3 O-ring
4 Union nut
5 Recess for O-ring
6 Thrust ring
7 Leakage overflow bore
8 Thrust ring
9 Union nut
10 Union nut
11 Connecting piece
12 Snap ring
13 Thrust ring
14 Compensating disks
15 Union nut
16 Thrust ring
17 HP line outer pipe
18 Internal pipe of HP line
19 Ball-type seal area
20 Leak-fuel connection
The HP fuel line is sealed by the thrust ring (8).
If leakage in the area of the thrust ring (8) or the HP line (2) occurs, the emerging fuel is routed to the
leakage chamber.
The leaking fuel is drained off without pressure via the leakage overflow-bore (7). The leakage chamber
is sealed toward the outside by the O-rings (3).
This prevents leakage egress.
The union is confirmed as being SOLAS-compliant by DNV and GL.
MS150110/00E 2013-10 | General Information | 29
TIM-ID: 0000045449 - 001