474 – AL Wiring FO
ZKP-Number: 2.8006.655
Wiring fault on FO
Yellow alarm; warning
Cause
Corrective action
Wire break or short circuit on
channel FO.
1. Check wiring (→ Page 248).
2. Contact Service.
475 – AL CR Engine Shutdown Trigger
ZKP-Number: 1.8010.009
Crash recorder was triggered by an engine shutdown.
Yellow alarm; warning
Cause
Corrective action
Crash recorder was triggered by
an engine shutdown.
u
Contact Service.
476 – AL Crash Rec. Init. Error
ZKP-Number: 1.8010.007
Initialization error of crash recorder.
Cause
Corrective action
Initialization error of crash
recorder.
u
Contact Service.
478 – AL Comb. Alarm Yel (Plant)
ZKP-Number: 2.8006.001
Yellow combined alarm from system
Yellow alarm; warning
Cause
Corrective action
Various causes possible.
u
Check for additional messages.
479 – AL Comb. Alarm Red (Plant)
ZKP-Number: 2.8006.002
Red combined alarm from system
Red alarm
Cause
Corrective action
Various causes possible.
u
Check for additional messages.
MS150110/00E 2013-10 | Troubleshooting | 155
TIM-ID: 0000045495 - 001