Level Plus
®
SoClean
®
Operation Manual
3. Introduction
3.1 Purpose and use of this manual
The content of this technical documentation and of its various
annexes is intended to provide information on mounting, installation
and commissioning by qualified service personnel according to IEC
60079-14 and local regulations or MTS trained service technicians.
3.2 Used symbols and warnings
Warnings are intended for your personal safety and for avoidance
of damage to the described product or connected devices. In this
documentation, safety information and warnings to avoid dangers that
might affect the life and health of personnel or cause material damage
are highlighted by the preceding pictogram, which is defined below.
4. Safety instructions
4.1 Intended use
The liquid level transmitter is intended to be used to measure the level
of liquid(s) contained by a structure as well as the temperature of the
liquid. The product may only be used for the applications defined
under item 1 to item 4 below and only in conjunction with third-party
devices and components recommended or approved by MTS Sensors.
As a prerequisite of proper and safe operation, the product requires
correct transport, storage, mounting and commissioning and must be
operated with utmost care.
1. Application does not exceed product’s performance specification in
section 5.6.
2. Product may only be installed in hazardous areas as specified by
approval certifications in section 12 following special conditions of
safe use outlined in section 12 or in safe areas.
3. The liquid(s) being measured are compatible with the selected
wetted parts of the product.
4. MTS floats should be used for proper functionality and safety
approval.
4.2 Foreseeable misuse
Important:
Before starting the operation of the equipment read this documentation
thoroughly and follow the safety information.
Symbol
Meaning
NOTICE
This symbol is used to point to situations
that may lead to material damage, and/or personal
injury.
4.3 Installation, commissioning and operation
1. Wear proper personal protection equipment such as hard hat,
safety shoes, flame resistant clothing, safety glasses, gloves, and
hearing protection.
2. Follow the specifications given in the technical documentation.
3. Two (2) individuals are recommended to conduct proper installati-
on, commissioning, and repair of the level transmitter.
4. Ensure the equipment used in a hazardous environment is selected
and installed in compliance with regulations governing the geogra-
phical installation and facility. Only install equipment that complies
with the types of protection relevant to the applicable classes,
division, zones, category, gas group, and temperature code.
5. Protect the sensor against mechanical damage during installation
and operation.
6. Do not use damaged products and secure them against unintentio-
nal use. Mark damaged products as being defective.
7. Connect the sensor very carefully and pay attention to the polarity
of connections. MTS recommends to not make connections while
power is live.
8. Before turning on power, ensure that nobody’s safety is jeopar-
dized by starting level transmitter and/or process.
9. Regularly follow preventative maintenance to prevent safety risks.
10. Make sure that no wire strands are loose or sticking out of the
terminal block connection which could short and cause a problem.
11. Make sure that no wire strands, including shield, are in contact
with the electronic module enclosure.
5. Product overview
The Level Plus
®
SoClean
®
Liquid-Level transmitter is a continuous
multi-functional magnetostrictive transmitter that provides product
level, interface level, and temperature to the user via Modbus, DDA,
Analog (4-20 mA), or HART
®
. Magnetostrictive technology is one of
the most accurate and repeatable level technologies available to date.
Forseeable misuse
Consequence
Process Temperature out of range
Signal Degradation, Possible Damage
to Sensor
See Section 5.6 for Specifications
Power Supply out of range
No Communication, Possible Dam-
age to Sensor
See Section 5.6 for Specifications
Process Pressure out of range
Possible Damage to Sensor,
See Section 5.6 for Specifications
Improper Chemical Compatibility
Possible Damage to Sensor,
Customer Must Select Wetted Mate-
rial that is compatible with liquid(s)
in tank
Modifying Sensor
Warranty Void, Hazardous Approval
Void Customer should contact facto-
ry for custom unit
Improper Grounding
Possible Damage to Sensor, Full
Protection Compromised,
See Section 7.6 for Grounding
Forseeable misuse
Consequence
Wrong sensor connection
Possible damage to electronics
See Section 7 for Electrical
Connections
Improper Installation
Physical damage to packaging
See Section 6 for Installation
Installation in unapproved
Hazardous Area
Potential Spark
See Section 12 for Agency
Information