7.7 Safety barriers
Refer to Table 3 for entity parameters and Table 4 for example safety
barriers
Entity parameters
Digital supply
(1 per LT)
Ui = 28 Vdc
Ii = 100 mA
Ci = 0.0 µF
Li = O mH
Pi = 700 mW
Digital
communication
(2 per LT)
Ui = 8.6 Vdc
Ii = 10 mA
Ci = 0.0 µF
Li = 0.0 mH
Pi = 21.5 mW
Analog
(1 per Loop)
Ui = 28 Vdc
Ii = 120 mA
Ci = 0 µF
Li = 5 µH
Pi = 840 mW
Table 3: Safety barrier entity parameter references
Table 4: Safety barrier entity parameter references
Supplier
STAHL
STAHL
STAHL
Type
9001/01-280-
100-101
9001/51-
280-110-141
9001/01-
086-010-101
Maximum voltage
28 Vdc
28 Vdc
8.6 Vdc
Maximum current
(each channel)
100 mA
110 mA
10 mA
Maximum power
(each channel)
700 mW
770 mW
21.5 mW
Number of chan-
nels
1
1
1
Interface
Modbus/DDA
HART
®
Modbus/DDA