Spare part 3: PTFE filter
Reference:
1. Filter element
2. Filter glass
3. Holding ring
4. Filter holder
Unscrew the holding ring (3).
Remove the filter glass (2).
Unscrew the filter holder (4).
Exchange the exhausted filter element with a new one (1).
Spare part 5: Disc filter PTFE
Power the system down.
Open the service flap of the MCU.
Carefully pull the filter from the clamps.
Unscrew the fittings from the exhausted filter.
Exchange the exhausted filter with a new one.
To make the entire system gas-tight, Teflon tape must be inserted
between the filter and the screw connection.