DCA220SSJU4F 60 HZ GENERATOR• OPERATION MANUAL — REV. #3 (02/10/17) — PAGE 27
OUTPUT TERMINAL PANEL FAMILIARIZATION
120 VAC GFCI Receptacles
There are two 120 VAC, 20 amp GFCI (Duplex Nema
5-20R) receptacles provided on the output terminal panel.
These receptacles can be accessed in any
voltage
change-over board
position. Each receptacle is protected
by a 20 amp circuit breaker. These breakers are located
directly above the GFCI receptacles. Remember the load
output (current) of both GFCI receptacles is dependent on
the load requirements of the U, V, and W output terminal
lugs.
Pressing the
reset button resets the GFCI receptacle after
being tripped. Pressing the
test button (See Figure 10) in
the center of the receptacle will check the GFCI function.
Both receptacles should be tested at least once a month.
Figure 10. G.F.C.I. Receptacle
Twist Lock Dual Voltage 240/139 VAC Receptacles
There are three 240/139V, 50 amp auxiliary twist-lock
(CS-6369) receptacles (Figure 11) provided on the output
terminal panel. These receptacles can be accessed in any
change-over board configuration.
Figure 11. 240/139V Twist-Lock Auxiliary
Receptacles
Each auxiliary receptacle is protected by a 50 amp circuit
breaker. These breakers are located directly above the
GFCI receptacles. Remember the load output (current) on
all three receptacles is dependent on the load requirements
of the
output terminal lugs.
Turn the
voltage regulator control knob
(Figure 12) on
the control panel to obtain the desired voltage. Turning the
knob clockwise will
increase the voltage, turning the knob
counter-clockwise will
decrease the voltage.
Figure 12. Voltage Regulator Control Knob
Removing the Protective Cover (Hard Wire Hookup
Panel)
The
output terminal lugs
are protected by a protective
cover (Figure 13). Un-screw the securing bolts (8) and
remove the cover to gain access to the output terminal lugs.
After the load wires have been securely attached to the
output terminal lugs, reinstall the protective cover, and
reinstall the retaining bolts
Figure 13. Protective Terminal Cover
(UVWO Terminal Lugs)
RETAINING
BOLT
PROTECTIVE
TERMINAL COVER
Содержание DCA220SSJU4F
Страница 4: ...PAGE 4 DCA220SSJU4F 60 HZ GENERATOR OPERATION MANUAL REV 3 02 10 17 NOTES ...
Страница 51: ...DCA220SSJU4F 60 HZ GENERATOR OPERATION MANUAL REV 3 02 10 17 PAGE 51 GENERATOR WIRING DIAGRAM BASLER OPTION ...
Страница 52: ...PAGE 52 DCA220SSJU4F 60 HZ GENERATOR OPERATION MANUAL REV 3 02 10 17 ENGINE WIRING DIAGRAM ECU 835 ...
Страница 54: ...PAGE 54 DCA220SSJU4F 60 HZ GENERATOR OPERATION MANUAL REV 3 02 10 17 NOTES ...
Страница 57: ...DCA220SSJU4F 60 HZ GENERATOR OPERATION MANUAL REV 3 02 10 17 PAGE 57 BATTERY CHARGER WIRING DIAGRAM OPTION ...
Страница 79: ...DCA220SSJU4F 60 HZ GENERATOR OPERATION MANUAL REV 3 02 10 17 PAGE 79 NOTES ...