OnCell G3111/G3151-HSPA Series
Cellular Network Settings
6-4
Username:
This is the user ID account.
Password:
This is the user password.
APN:
Before using the GPRS/UMTS/HSDPA also need APN (Access Point Name) must be added as an IP
gateway initialization command. Detailed instructions are shown below.
Connection control
Connect Rule
Disconnect Rule
GPRS
Always on/None
Always on after power on
None
Trunk
Periodically connect/
inactivity time
Periodically connect (based on the connection
interval setting) attempt to connect to
UMTS/HSDPA first then GPRS after powering
on.
Inactivity time is up
Trunk
Remote host fail/
remote host recovered
Remote Ethernet host has failed. The OnCell
G3111/G3151-HSPA will keep pinging the
remote host over the Ethernet every 3 seconds
after powering on. After failing to connect 5
times in a row, the data from the serial device
will be sent through the HSDPA/UMTS first
then GPRS connection.
When the remote
Ethernet host
returns to normal,
data will revert to
being sent over
Ethernet after 5
continuous
successful pings.
Backup
Connection interval (default = 5 min):
The time interval of the periodic connect function.
Ping remote host:
Key in the IP address of the remote host.
SMS Mode
Short Message Service (SMS) is a telecommunications protocol that allows sending “short” (160 characters or
less) text messages. It is available on most digital mobile phones and some personal digital assistants with
built-in wireless capability. Setting Cellular connection method to SMS Mode allows the ability to enable SMS
Tunnel Mode in the Serial Operation. Refer to
Chapter 7, Serial Port Operation Mode Settings