OnCell G3111/G3151-HSPA Series
Software Installation/Configuration
B-19
6.
Execute
/tmp/oncell_realtty/mxinst
.
For RedHat AS/ES/WS and Fedora Core1, append an extra argument as follows:
# /tmp/oncell_realtty/mxinst SP1
The shell script will install the driver files automatically.
7.
After installing the driver, you will be able to see several files in the
/usr/lib/oncell_realtty/driver
folder:
>
mxaddsvr
(Add Server, mapping tty port)
>
mxdelsvr
(Delete Server, un-mapping tty port)
>
mxloadsvr
(Reload Server)
>
mxmknod
(Create device node/tty port)
>
mxrmnod
(Remove device node/tty port)
>
mxuninst
(Remove tty port and driver files)
At this point, you will be ready to map the OnCell serial port to the system tty port.
Mapping TTY Ports
Make sure that you set the operation mode of the desired OnCell G3111/G3151-HSPA serial port to Real COM
mode. After logging in as a super user, enter the directory
/usr/lib/oncell_realtty/driver
and then execute
mxaddsvr
to map the target OnCell serial port to the host tty ports. The syntax of
mxaddsvr
is as follows:
mxaddsvr
[OnCell IP Address] [Total Ports] ([Data port] [Cmd port])
The
mxaddsvr
command performs the following actions:
1.
Modifies
oncellreald.cf
.
2.
Creates tty ports in directory /dev with major & minor number configured in
oncellreald.cf
.
3.
Restarts the driver.
Mapping tty ports automatically
To map tty ports automatically, you may execute
mxaddsvr
with just the IP address and number of ports, as
in the following example:
# cd /usr/lib/oncell_realtty/driver
# ./mxaddsvr 192.168.3.4 1
In this example, one tty port will be added, with IP 192.168.3.4, with data port 950 and command port 966.
Mapping tty ports manually
To map tty ports manually, you may execute
mxaddsvr
and manually specify the data and command ports, as
in the following example:
# cd /usr/lib/oncell_realtty/driver
# ./mxaddsvr 192.168.3.4 1 4001 966
In this example, one tty port will be added, with IP 192.168.3.4, with data port 4001 and command port 966.