OnCell G3111/G3151-HSPA Series
Cellular Network Settings
6-2
Cellular Settings
From the left navigation panel, click
Network Settings
Cellular Settings
to configure the cellular
operation settings. The various configuration items are described below:
Type:
The OnCell G3111/G3151-HSPA supports 3 types of operation modes. You may choose from GSM (CSD),
GPRS/EDGE/UMTS/HSDPA/HSPA (PSD, 2G/3G), and SMS.
SIM PIN:
This is a pin code that locks the SIM card until you enter the correct code. Use the pin to protect your
account. The default code is set by the Service Provider. Note that a cell phone must be used to change the PIN.
Band:
Setting the value to “Auto” will allow the IP gateway to automatically negotiate with the local operator
and find an appropriate band. Or users can specify a particular band to use.
Additional settings for each of the three modes are described in the following subsections.
GSM (CSD) Connection
PPP Mode
: PPP provides standard PPP dial-out service.
PPPD Mode
: PPPD (PPP Daemon) is used for dial-in services, since it provides PPP services only when
receiving a request from a remote PC.
Destination IP address:
Source IP address:
IP netmask:
These three values on the left will be filled in automatically by the remote side if
it is not specified by the user.
TCP/IP compression (default=Disable)
: The setting of this field depends on whether the remote user’s
application requests compression.
Inactivity time (default=0 ms)
: This field specifies the idle time setting for auto-disconnection. A setting of
0 ms will cause the port to remain connected even if idle.
Link quality report (default=Disable)
: Setting this field to
Enable
allows the OnCell G3111/G3151-HSPA
to check the PPP connection status with a base station that supports link monitoring.
Outgoing PAP ID:
This is the dial-out user ID account.
PAP password:
This is the dial-out user password.
Incoming PAP check (default=None):
This field allows you to configure the method used, if any, to verify
a user’s ID and authorization.
Содержание OnCell G3111-HSPA series
Страница 11: ...OnCell G3111 G3151 HSPA Series Getting Started 2 2 Panel Layout OnCell G3111 G3151 HSPA...
Страница 82: ...OnCell G3111 G3151 HSPA Series System Management Settings 9 18...
Страница 116: ...OnCell G3111 G3151 HSPA Series Pinouts and Cable Wiring C 3 Pin Assignments for DB25 Male and Female Connectors...