OnCell G3111/G3151-HSPA Series
Software Installation/Configuration
B-20
Removing Mapped TTY Ports
After logging in as root, enter the directory
/usr/lib/oncell_realtty/driver
and then execute
mxdelsvr
to
delete a server. The syntax of mxdelsvr is:
mxdelsvr
[IP Address]
Example:
# cd /usr/lib/oncell_realtty/driver
# ./mxdelsvr 192.168.3.4
The following actions are performed when executing
mxdelsvr
:
1.
Modify oncellreald.cf.
2.
Remove the relevant tty ports in directory
/dev
.
3.
Restart the driver.
If the IP address is not provided in the command line, the program will list the installed servers and total ports
on the screen. You will need to choose a server from the list for deletion.
Removing Linux Driver Files
A utility is included that will remove all driver files, mapped tty ports, and unload the driver. To do this, you only
need to enter the directory
/usr/lib/oncell_realtty/driver
, then execute
mxuninst
to uninstall the driver.
This program will perform the following actions:
1.
Unload the driver.
2.
Delete all files and directories in
/usr/lib/moxa_oncell
3.
Delete directory
/usr/lib/moxa_oncell
4.
Modify the system initializing script file.
Moxa OnCell UNIX Fixed TTY Driver
Installing the UNIX Driver
1.
Log in to UNIX and create a directory for the Moxa TTY. To create a directory named
/usr/etc
, execute the
command:
# mkdir –p /usr/etc
2.
Copy
moxa_oncell_fixedtty.tar
to the directory you created. If you created the
/usr/etc
directory
above, you would execute the following commands:
# cp moxa_oncell_fixedtty.tar /usr/etc
# cd /usr/etc
3.
Extract the source files from the tar file by executing the command:
# tar xvf moxa_oncell_fixedtty.tar
The following files will be extracted:
README.TXT
oncellttyd.c
--- source code
oncellttyd.cf
--- an empty configuration file
Makefile
--- makefile
VERSION.TXT
--- fixed tty driver version
FAQ.TXT
Содержание OnCell G3111-HSPA series
Страница 11: ...OnCell G3111 G3151 HSPA Series Getting Started 2 2 Panel Layout OnCell G3111 G3151 HSPA...
Страница 82: ...OnCell G3111 G3151 HSPA Series System Management Settings 9 18...
Страница 116: ...OnCell G3111 G3151 HSPA Series Pinouts and Cable Wiring C 3 Pin Assignments for DB25 Male and Female Connectors...