23/60
ST_PM_ Installation Manual_EN_V1.0 | 08.2020
Copyright © 2020 Mounting Systems GmbH
6.5.2.2
Set horizontal alignment to 0°
The post extension was mounted with an angular tolerance of ±1°. To compensate for
this, align the rafter (5) to 0° horizontally using the spirit level.
While doing so, rotate the threaded spindle to the right or left by hand. 4 full 360 °
rotations of the spindle will result in an angle correction of ±1°, depending on the direction.
Align the longitudinal slots on the spindle ends the same way on all adjusting devices (1).
Figure 10 Setting up the adjusting device