CT34002a_e.doc / Nov-15
Page 32 / 42
7.3.
Display of Actual Values
During normal operation it is possible to display an actual value. Two LEDs at the front panel
indicate the actual value displayed. You can scroll the actual value on the display by Scroll
Display command, which can be assigned either to a key or to an input. Parameter F08.071
“Default Display” selects the actual value to be displayed after power up of the unit.
Nr. Display
L1 (red)
L2 (yellow)
0 Display OFF (only two decimal points are lit to indicate
operation state)
OFF
OFF
1 Position error (differential counter)
OFF
OFF
2 Position error (bar graph display, see diagram below)
OFF
OFF
3 Actual Master speed
The speed display can be scaled by the two parameters
F03.029 Speed Display Factor and F03.030 Speed:
030
.
03
029
.
03
]
[
F
F
Hz
frequency
Master
value
Display
If you want to display a decimal point with the speed
value you can select the position of the decimal point by
parameter F03.031 Speed Display Dec.Point.
ON
OFF
4 Master encoder pulse counter
OFF
ON
5 Cutting roll position scaled in encoder increments
ON
ON
6 Cutting pulse distance scaled in encoder increments
Flashing
OFF
7 Actual cutting length scaled in length units
OFF
Flashing
8 Batch counter
Flashing
Flashing
Slave lags Master
Slave leads Master
-4 ... 0 ... +4
+5 ... +8
+9 ... +16
+17 ... +32
+33 ... +64
> +64
Bar graph display with reference to the actual position error
The diagram shows positive errors only (Slave lags Master). Negative errors are mirror-inverted
.