F02
Range
Default
F02.011
Sampling Time:
Sets the internal digital feed forward control with
respect to dynamics and resolution.
Lower set values result in faster response, but less
accuracy of the feed forward signal. Higher set values
result in better accuracy, but slower response with
sudden speed changes.
Feed forward signals with lower accuracy do not at all
affect speed accuracy of the synchronizing process, but
only might cause slight angular errors.
Depending of the maximum Master encoder frequency,
the subsequent setting can be recommended:
0.001 … 9.980
(seconds)
0.001
fmax
Sampling -Time
1 kHz
0.100 s
3 kHz
0.033 s
10 kHz
0.010 s
30 kHz
0.003 s
≥
100 kHz
0.001 s
F02.012
Wait Time:
Not applicable, leave at default setting.
0.01
… 9.99
9.99
F02.013
Max. Master Frequency:
Sets the expected maximum input frequency on the
Master encoder input, i. e. the line encoder frequency at
maximum line speed. You should add a 10% reserve to
the real maximum frequency. The unit will not process
frequencies higher than this setting.
0.1
…300000.0
(Hz)
30000.0
F02.014
Cuts per Revolution:
Number of cuts per revolution of the cutting roll.
Set this register to 1 when your cutting roll has only one
tool at its circumference to perform one single cut per
revolution.
When you have mounted two or more tools around the
cutting roll, there are two different ways of setting this
register to perform two or more cuts by every revolution
of the cutting roll:
1…99