CT34002a_e.doc / Nov-15
Page 26 / 42
6.2.7.
Characteristics and functions of the Control Inputs
F06
Range
Default
F06.049 Switching characteristics of input „Cont.1“
0 … 7
0
0=
NPN (switch to -), function active LOW
1=
NPN (switch to -), function active HIGH
2=
NPN (switch to -), rising edge
3=
NPN (switch to -), falling edge
4=
PNP (switch to +), function active LOW
5=
PNP (switch to +), function active HIGH
6=
PNP (switch to +), rising edge
7=
PNP (switch to +), falling edge
F06.050 Function assignment to input „Cont.1“
0 … 16
6
0=
No function
1=
Reset
2=
Start
3=
Immediate Cut
4=
Homing
For more details about these
functions see section 7.1
5=
n.a.
6=
Cutting Pulse
7=
Store to EEPROM
8=
Scroll Display
9=
Parameter Input Disable
10= Jog / Trim forward
11= Jog / Trim backward
12= Clear Batch Counter
13= n.a.
14= Read front thumbwheels (model CT 641 only)
15= Clear Error
16= n.a.
F06.051 Switching characteristics of input „Cont.2“
See „Cont.1“ (F06.049)
F06.052 Function assignment to input „Cont.2“
See „Cont.1“ (F06.050)
F06.053 Switching characteristics of input „Cont.3“
See „Cont.1“ (F06.049)
F06.054 Function assignment to input „Cont.3“
See „Cont.1“ (F06.050)
F06.055 Switching characteristics of input „Cont.4“
0 – 3
0= NPN (switch to -) function active LOW
no edge-triggered functions are
possible with Cont.4
1= NPN (switch to -) function active HIGH
2= PNP (switch to +), function active LOW
3= PNP (switch to +), function active HIGH
F06.056 Function assignment to input „Cont.4“
See „Cont.1“ (F06.050)