8 Settings via the MICT
60
Rev. 08/2018
8.9.4
Miscellaneous – Communication
CAN
Via the field
CAN
, deactivate or activate the CAN interface of the device.
–
ALL-IN-ONE (J1939)/CANopen
Select the desired protocol, depending on whether you want to set the communication for
the ALL-IN-ONE or for another master control.
–
Source Address/CANopen Node ID
In the protocol
ALL-IN-ONE (J1939)
the source address can be assigned between 0 and 253.
In the CANopen protocol, a CANopen node ID from 1 to 127 can be assigned. Note that IDs
cannot be assigned more than once.
–
Baudrate
Select the desired data transfer rate from the list. In the protocol
ALL-IN-ONE (J1939)
,
250 kbit/s and 500 kbit/s are available for selection. In the CANopen protocol, a baud rate
from 50 kbit/s to 1 Mbit/s can be set. For both protocols, we suggest the use of a baud rate
of 250 kbit/s.