8 Settings via the MICT
54
Rev. 08/2018
–
Unknown
This option corresponds to the factory setting and cannot be reassigned once the device has
been changed.
–
None
Select this option if you want to shut down or store your VariStep3 stepper motor driver
temporarily. In addition, this option can be selected if the VariStep3 stepper motor driver
was configured for one device type and is then to be used for another device type. For this,
also read the information box
Changing the device type
. If the device type has been changed
to
None
and the modified configuration has been downloaded to the device, the
Status
and
Manual/Auto
LEDs are flashing orange.
Note the stepper motor revision
The revision of the stepper motor can be identified from the nameplate on
the stepper motor of your VariFuel2.
VariFuel2 stepper motors whose revisions are not stated on the nameplate
or which are supplied without a nameplate are revision A stepper motors.
For revision A, select the entry for your VariFuel2 type without a revision
specification under
External Device
(e.g.
VF2 200-120
for a VariFuel2 type
200-120 with revision A stepper motor).
If no VariFuel2 types with matching stepper motor revision are displayed
under
External device
, the VariFuel database of your MICT is not up-to-date.
In this case, perform an online update. For further information, refer to the
section
Online Update Settings
on page 46.