APEX1000 All-Purpose Edge QAM Software Version 2.4.x • Installation and Operation Manual
236
573408-001-a
Chassis Redundancy Status window parameters
Parameter
Description
Redundancy Status
Redundancy Role
Describes the functional role of the designated APEX.
Values are:
•
Primary
– The APEX which is typically active
•
Secondary
– The APEX which is typically standing by
Primary APEX
Status
Describes the functional state of the primary APEX. Values are:
•
Unknown
– State of the Primary is not known. (Heartbeat not received)
•
Active
– Primary RF outputs are active
•
Standby
– Primary RF outputs are muted. Waiting to become active
•
Fault
– The Primary has experienced a fault
•
Suspended
– User has enabled
on the Primary APEX
The default is Standby.
Secondary APEX
Status
Describes the functional state of the secondary APEX. Values are:
•
Unknown
– State of the Secondary is not known. (Heartbeat not received)
•
Active
– Secondary RF outputs are active
•
Standby
– Secondary RF outputs are muted. Waiting to become active
•
Fault
– Fault on the Secondary
•
Suspended
– User has enabled
on the Secondary APEX
The default is Unknown.
Redundancy
State/Availability
Shows the availability state of the 1:1 redundancy system.
Values are:
Available
1. Primary in active state received heartbeat
from Secondary in standby state
or
2. Secondary in active state received heartbeat
from primary in standby state
• Configurations are synchronized
• No critical faults
Protected
1. Primary in fault state received heartbeat from
Secondary in active state
or
2. Secondary in fault state received heartbeat
from Primary in active state
• Configurations are synchronized
Unavailable
•
Timeout waiting for heartbeat from other
APEX in redundancy pair
•
Configuration not synchronized
•
Primary or Secondary APEX in fault or
suspend state
Synchronizing
•
Synchronizing configuration between active
and standby APEXs