B
Configuration • QAM RF Redundancy Configuration
APEX1000 All-Purpose Edge QAM Software Version 2.4.x • Installation and Operation Manual
114
573408-001-a
Item
Definition/Range
Failover Configuration
Auto
Switchback
This is the enable/disable of automatic switch back to the previous RF port from backup
for QAM RF redundancy.
•
When
enabled
, switch back to the previous RF port will automatically occur when the
RF port comes back online.
•
When
disabled
, you must force back to the previous RF port using the
apexQamRfRedundConfigForceSwitch
command.
Note: An error on the backup port or on the REM1000 overrides this setting.
Suspend
Failover
Enables and disables suspending of RF failover. Prevents failovers to or from the backup
RF port.
Note: Force Failover overrides this setting. Also, an error on the backup port or on the
REM1000 overrides this setting.
Force Failover
From
This command:
•
Forces a switch of an RF Port to or from the
backup
•
Selects which RF Port to switch from
•
Overrides Suspend Failover
When any of the RF Ports are selected, the
Force
button becomes available:
Selecting
Force From Backup
will force back to the
failed primary displayed in the APEX RF Port Failure
field.
After a failover, you will still map service, PIDs,
streams to the primary outputs, not the backup
outputs. PID Remapping, Operating Mode,
Encryption selection, etc., will all be done on the
primary regardless of the current failover state. You
will not be able to select any backup streams for any
configuration.
Note: An error on the backup port or on the
REM1000 overrides this setting. The APEX does not
allow
force to
backup mode.