Manual Routing • Input Stream Redundancy
APEX1000 All-Purpose Edge QAM Software Version 2.4.x • Installation and Operation Manual
149
573408-001-a
Input Stream Redundancy window field definitions
Window Section
Definition
Redundancy
Type
Use to select between
redundancy.
Caution: Redundancy Type cannot be changed while there are currently
any active mappings (all mappings must be disabled prior to changing the
redundancy type).
Monitor Period
(s)
Shows the time in seconds over which Redundant Gigabit Ethernet UDP
Port Pairs will be monitored.
Range: 1 – 30 seconds
•
This is the number of seconds that the Primary and Secondary will be
compared to each other, before determining if a fail over or fall back is
necessary.
The higher the setting, the longer the delay between when a loss of input
data occurs and when the APEX1000 will perform a fail over.
Note: Only applicable when the Redundancy Type is set to Hot/Hot.
Auto-Switchback
Range: On/Off
When On, the APEX will automatically fallback to the Primary, when it
determines that the primary input stream has been restored.
Note: Only applicable when the Redundancy Type is set to Hot/Hot.
Hold Time (s)
This is the time in seconds to wait before switching back to the Primary of
a Redundant Gigabit Ethernet UDP Port pair after the Primary is healthy.
Range: 0 – 3600 seconds
Note: Only applicable when the Redundancy Type is set to Hot/Hot.
Force to Primary
Force all input streams to use the primary stream in the input stream pair
(used if
stream redundancy
is configured).
Note: Not applicable for Host Input streams.
Global
Settings
Force to
Secondary
Force all input streams to use the secondary stream in the input stream
pair (used if
stream redundancy
is configured).
Note: Not applicable for Host Input streams.
Clear
Clear is an EM function that sets a row to default values. Check this box
and press
Apply
to cause the data for
all
rows to be cleared (delete
entries).
•
Any multicast or redundancy setup will be disabled.
•
To clear selected rows, click each individual checkbox as desired.
Index
Index of Input Stream Redundancy table.
Range: 1 – 768
Input Interface
Number of the input type from which to obtain data (GigE 1 – 4). The Input
IF for a row must be either GigE1 and GigE2 or GigE3 and GigE4.
Select an Enabled GigE Interface or N/A to disable a row.
Input UDP Port
Input UDP port from which to obtain data.