APEX1000 All-Purpose Edge QAM Software Version 2.4.x • Installation and Operation Manual
119
573408-001-a
Window Section
Definition/Range
UDP Ports
Open
Indicates the number of UDP ports currently opened. You can
change the IP and Subnet only if the UDP Ports Open value
equals 0.
Number Input
TS
Indicates the number of input streams currently assigned to an
interface. Input streams are assigned when a mapping is added to
the APEX. This indicates whether or not an interface is in use.
Caution: You cannot change the IP address, subnet mask, and
Enabled settings if there are any input streams assigned to an
interface.
IGMP Version
Shows the Internet Group Management Protocol version.
Default
Gateway
Shows the IP address of the default gateway for GigE 1/2 and GigE
3/4.
Enable
Interface
Redundancy
Enables or disables GigE interface redundancy.
Interface Redundancy is based on GigE link status. Loss of link will
cause an interface to failover to the backup.
Suspend
Failover
Enables or disables Suspend Failover (prevents failovers to or from
the backup interface).
Range: Enabled/Disabled (default)
Force Failover
Button
Initiates a force failover from one GigE interface to the other.
Note: Force failover overrides the Suspend Failover setting.
GigE Interface
Settings
(Continued)
Status
Read–only display. Indicates whether GigE interface redundancy is
enabled or disabled.
Enable Auto-
Switchback
Enables or disables Auto-Switchback to the primary GigE interface
(when the primary interface is back online).
Auto-
Switchback
Period (s)
This is the period of time (in seconds) to wait before switching back.
Interface
Redundancy
Global
Failover Alarm
Occurs when a primary GigE interface has failed over to the backup
GigE interface, or the user has initiated a force failover from the
primary GigE interface.
Help Button
Available in selected windows. Click to view corresponding help topics.