50
3.
When extending the keypad cable to install the keypad, M3 screws can be used to fix the
keypad onto the door plate, or optional keypad installation bracket can be used. If you need
install the keypad on another position rather than on the inverter, use a keypad extension cable
with a standard RJ45 crystal head.
4. No.
Name
Instruction
1
State
Indicator
(1)
RUN
Running indicator;
LED off – the inverter is stopped;
LED blinking – the inverter is in parameter
autotune
LED on – the inverter is running
2)
TRIP
Fault indicator;
LED on – in fault state
LED off – in normal state
LED blinking – in pre-alarm state
(3)
QUICK/JOG
Short-cut key indicator, which displays
different state under different functions, see
definition of QUICK/JOG key for details
2
Button
area
(4)
Function key
The function of function key varies with the
menu;
The function of function key is displayed in
the footer
(5)
(6)
(7)
Short-cut key
Re-definable. It is defined as JOG function
by default, namely jogging. The function of
short-cut key can be set by the ones of
P07.12, as shown below.
0: No function ;
1: Jogging (linkage indicator (3); logic : NO);
2: Reserved;
3: FWD/REV switch-over (linkage indicator
(3); logic: NC) ;
4: Clear UP/DOWN setting (linkage indicator
(3) logic: NC) ;
5: Coast to stop (linkage indicator (3); logic:
NC) ;
6: Switching running command reference
mode in order (linkage indicator (3); logic:
NC) ;
7: Reserved;
Note: After restoring to default values,
Содержание MSI350 Series
Страница 1: ...MSI350 SERIES INVERTER USER MANUAL...
Страница 2: ...2...
Страница 34: ...34 4 2 6 Vertical installation Fig 4 5 Vertical installation...
Страница 38: ...38 Fig 4 10 3PH 380V 30 37kW Fig 4 11 3PH 380V 45 110kW Fig 4 12 660V 22 45kW...
Страница 39: ...39 Fig 4 13 660V 55 132kW Fig 4 14 380V 132 200kW and 660V 160 220kW...
Страница 40: ...40 Fig 4 15 380V 220 315kW and 660V 250 355kW...
Страница 71: ...71...
Страница 83: ...83 When selecting customized V F curve function users can set the reference channels and...
Страница 90: ...90...
Страница 96: ...96...
Страница 101: ...101...
Страница 147: ...147...
Страница 260: ...260 7 6 Analysis on common faults 7 6 1 Motor fails to work...
Страница 261: ...261 7 6 2 Motor vibrates...
Страница 262: ...262 7 6 3 Overvoltage...
Страница 263: ...263 7 6 4 Undervoltage...
Страница 264: ...264 7 6 5 Unusual heating of motor...
Страница 265: ...265 7 6 6 Inverter overheating...
Страница 266: ...266 7 6 7 Motor stalls during ACC...
Страница 267: ...267 7 6 8 Overcurrent...
Страница 318: ...318 The following figure shows the external wiring of the extension card used in combination with a push pull encoder...
Страница 336: ...336 A 6 5 PROFINET communication card EC TX509...
Страница 339: ...339 A 7 Programmable extension card function description A 7 1 Programmable extension card EC PC501 00...
Страница 380: ...380...
Страница 386: ...386...
Страница 387: ...387...
Страница 388: ...388...