MB1009-054    MAESTRO, RECIRCULATING BOX, 54IN UNITS 

 

MB1009-066   MAESTRO, RECIRCULATING BOX, 66IN UNITS 

 

MB1009-072   MAESTRO, RECIRCULATING BOX, 72IN UNITS 

 

MB1009-084   MAESTRO, RECIRCULATING BOX, 84IN UNITS 

 

MB1009-096   MAESTRO, RECIRCULATING BOX, 96IN UNITS 

 

MB1010  MAESTRO, FORMALIN DISPENSE 

 

MB1011  MAESTRO, FORMALIN COLLECTION 

 

MB1012  MAESTRO, END RINSE 

 

MB1016  MAESTRO, FAUCET, FOOT PEDAL, PNEUMATIC 

 

MB1017  MAESTRO, FAUCET, INFRARED 

 

MB1019  MAESTRO, FUME DETECTION SYSTEM 

 

MB1020  MAESTRO, AUX SIDE VENT PORT 

 

MB1021  MAESTRO, GARBAGE DISPOSAL, 1 H.P. WITH WATERJET 

 

MB1022  MAESTRO, BMS SYSTEM 

 

MB1023  MAESTRO, CABINET DOORS 

 

MB1023-048   MAESTRO, CABINET DOORS, 48IN 

 

MB1023-054   MAESTRO, CABINET DOORS, 54IN 

 

MB1023-066   MAESTRO, 66IN DOORS 

 

MB1023-072   MAESTRO, 72IN DOORS 

 

MB1023-084   MAESTRO, CABINET DOORS, 84IN 

 

MB1023-096   MAESTRO, CABINET DOORS, 96IN 

 

MB1024  MAESTRO, GARBAGE DISPOSAL, 1/2 H.P. 

 

MB1024C  MAESTRO, GARBAGE DISPOSAL, 1/2 H.P. (CANADA UL-APPROVED) 

 

MB1026  SAFETY SPLASH SHIELD 

 

MB1027  POWER CORD, NEMA PLUG L14-20P 

 

MB1029  MAESTRO, 2X Quick Coupler Base Magnifier 

 

MB1030  MAESTRO, LEG FRAME, 60IN 

 

MB1030-048   MAESTRO, LEG FRAME, 48IN 

 

MB1030-054   MAESTRO, LEG FRAME, 54IN 

 

MB1030-066   MAESTRO, LEG FRAME, 66IN 

 

MB1030-072   MAESTRO, LEG FRAME, 72IN 

 

MB1030-084   MAESTRO, LEG FRAME, 84IN 

 

MB1030-096   MAESTRO, LEG FRAME, 96IN 

 

MB1031  MAESTRO, RED GFCI AND USB OUTLETS 

 

MB1032L  MAESTRO, HAND SPRAY, FOR LEFT HAND UNITS 

 

MB1032R  MAESTRO, HAND SPRAY, FOR RIGHT HAND UNITS 

 

MB1033  MAESTRO, FORMALIN DISPENSE & COLLECTION 

 

MB1034  UVC DISINFECTION FOR MAESTRO 

 

MB1035  UVC DISINFECTION RETROFIT KIT 

 

MB1036L  MAESTRO, HANDSPRAY & END RINSE, LEFT HAND 

 

MB1036R  MAESTRO, HANDSPRAY & END RINSE, RIGHT HAND 

 

MB1037  MAESTRO, FORMALIN DISPENSING TAP 

Содержание Maestro MB1000 Series

Страница 1: ...Installation Service User Manual Maestro series MB1000 MAN rev 1 Installation Service and User Instructions Grossing Station MB1000 MG1000 series JUL 2021 Version 1...

Страница 2: ...ator at the address below Mopec 800 Tech Row Madison Heights MI 48071 Phone 1 800 362 8491 email customerservice mopec com TRADEMARKS Is a registered trademark of Mopec Ensemble Pegboard Is a register...

Страница 3: ...3 Technical Data 9 2 4 Product Compliance 9 2 5 Product elements 9 2 6 Warranty Statement 10 3 Installation 11 3 1 How to unpackage your workstation 11 3 1 1Check for freight damage 11 3 1 2Uncrating...

Страница 4: ...5 Factory Options Accessories 19 5 1 Standard Features 19 5 1 1The Maestro is equipped with the following standard features 19 5 1 2Customization CUST Modification MOD 19 5 2 Factory Configured Option...

Страница 5: ...tion 34 6 2 14 Integrated Camera System Options 35 6 2 15 BMS Building Management System Connection 36 6 2 16 Fume Detection 37 6 3 What to Do in Emergency and Exceptional Situations 37 7 MAINTENANCE...

Страница 6: ...Power Supply Panel Service 47 8 2 3Garbage Disposal Jams 48 8 2 4Checking Disposal Breakers 48 8 2 5Faucet Hand Spray End Rinse Service panel 49 8 2 6Backflow prevention and Service 50 9 Documentation...

Страница 7: ...er the measurement of the station from the front of the work surface to the rear of the station or the depth of the sink REF references a section of the manual for more information 1 3 Models covered...

Страница 8: ...not hazard related 1 5 Obtaining Instructions Instructions are typically supplied digitally stored on a USB type flash drive that is zip tied to the main faucet spout At anytime the most current revi...

Страница 9: ...ntrols for water a disposal and efficient exhaust options Virtually everything is at your fingertips 2 2 Process Overview The Maestro is for grossing study and not intended to be used as a medical dev...

Страница 10: ...specifications If a warranty claim is made within one 1 year from the date of shipment or the date of installation if installation is provided by Mopec the defective or nonconforming Product or Part t...

Страница 11: ...he corner posts of the crate Pull downward and then sideways to break away from the base Remove all the bracing at the bottom of the skid Note the small 2 x 4 blocks nailed to prevent the unit from mo...

Страница 12: ...will slide on other hard smooth surfaces Remove the unit from the dollies and set on the Masonite boards Tip the unit forward to lower the back leveling feet so the bottom of the foot is approximatel...

Страница 13: ...es at this time o The workstation utilizes a multiwire branch circuit 1 115 1 60 20amp circuit labeled L1 powers the controls and power outlets 1 115 1 60 20amp circuit labeled L2 powers the disposal...

Страница 14: ...htening the connections 3 1 8 Ventilation connection in house ventilation At this point the unit should still be in its lowest elevation position if not please lower to the lowest position in order to...

Страница 15: ...uct 3 3 1 Storage in place Adjust the elevation to its lowest position for long term storage Turn off the water supply to the unit Open and drain all lines including hand spray o If the temperature co...

Страница 16: ...er skirting is 304 stainless steel along with the frame cross connectors 3 4 2 Ferrous Steel The only ferrous steel used on the Maestro is in the lower frame weldment where the linear actuators mount...

Страница 17: ...n in the Hood section After the unit is switched on the touch screen controller will start to boot up While the system microprocessor boots up you will see the startup screen saver and may see the scr...

Страница 18: ...and stay on with a button push To turn off simply press the button again Standard Maestro units utilize a dry hp disposer unit You must run the water to assist in flushing the contents down the drain...

Страница 19: ...ting board white Two 2 wire ports for cord management 1 2 Hp Disposal dry Magnetic instrument bar One 1 large and one 1 small organizer bin Ensemble Pegboard System C Fold Paper Towel Dispenser Single...

Страница 20: ...66IN DOORS MB1023 072 MAESTRO 72IN DOORS MB1023 084 MAESTRO CABINET DOORS 84IN MB1023 096 MAESTRO CABINET DOORS 96IN MB1024 MAESTRO GARBAGE DISPOSAL 1 2 H P MB1024C MAESTRO GARBAGE DISPOSAL 1 2 H P C...

Страница 21: ...2 Available Accessories AX001 PEGBOARD MONITOR MOUNT AX002 PEGBOARD REQUISITION HOLDER AX003 PEGBOARD TICKET HOLDER AX004 PEGBOARD MARKING DYE HOLDER AX006 PEGBOARD 14 SHELF AX008 PEGBOARD SMALL BIN...

Страница 22: ...N MONITOR KEYBOARD MOUNT AX071 DICTATION STAND 7 x5 x8 55DEG SS AX072 MAESTRO PEGBOARD 7IN SHELF AX073L MAESTRO CASSETTE LABELING SHELF LEFT SIDE AX073RMAESTRO CASSETTE LABELING SHELF RIGHT SIDE AX074...

Страница 23: ...MAESTRO HOOD AX133 PATHCAM MICROSCOPE CAMERA MOUNT MAESTRO 5 3 3 Customization CUST If your factory Accessory has been customized the Model No will show a CUST suffix 5 3 4 New Accessories New Maestr...

Страница 24: ...o CAUTION The Maestro is equipped with a Touch Screen pressing hard on the screen will result in damage 6 1 2 Startup Turn on the Maestro from the a Power Switch located on the hood column above the s...

Страница 25: ...ns are only informational and do not accept button presses The setpoints and details of the status icon functions are within the settings menu tables 6 1 5 Alerts The Maestro is continuously monitorin...

Страница 26: ...t will display on the top of the screen in red This feature is there to allow the system to be tested with setup unlocked 6 1 7 User The Maestro has the ability to save user adjustable settings Lightl...

Страница 27: ...Use Maestro Standard Features Options 6 2 1 Lighting standard The Maestro has recessed LED lights integrated into the hood and a few supplemental light options available Overhead LED dimmer is adjust...

Страница 28: ...is simple and safe The FAS uses a series of fans to provide supplemental airflow at the front edge of the workstation directed at the backdraft vent This helps push and pull any outgassed fumes from t...

Страница 29: ...other user inputs are activated 6 2 4 Foot Pedal Faucet Option The Foot Pedal option controls the on off of mixed water to the Faucet Foot Pedal Hot Cold Mixing Valve The foot pedal is mounted to a fl...

Страница 30: ...n be used to dispense a given amount of water per a laboratory process To adjust water ON time touch the Water Timer button Adjust the time ON setting with the up down arrows The water will turn on wi...

Страница 31: ...ntended for facilities that do not have available HVAC exhaust flow available for temporary use or in limited use environments The backdraft air is pulled through the hood by variable speed blowers an...

Страница 32: ...e Recirculating system REF 6 2 8 The filter timer function is intended to set a reminder and Alert on the touch screen when it is time to change the filters in the system Set the timer by touching the...

Страница 33: ...ray mixed water Flow rate can be adjusted by both the trigger and the mixing valve 6 2 11 End Rinse Option The End Rinse option is installed opposite the sink and utilizes the hand spray hot cold mixi...

Страница 34: ...ense Pump button located just inside the knee panel The system is equipped with level sensors and will turn off the pump when full o An empty system will typically transfer 5 gallons when filling The...

Страница 35: ...eference is to eliminate the fluid trap simply trim the line back short enough that the fluid drains completely into the carboy You will have to bend down into the knee space to disconnect now Unscrew...

Страница 36: ...stems are covered in their own product specification and user manual See www mopec com for the latest information 6 2 15 BMS Building Management System Connection Mopec BMS Building Management System...

Страница 37: ...o as it will cause false positive alerts and reduce the sensor s operating life Mopec Fume detection option MB1019 operation is covered separately in its own manual See www mopec com for the latest 6...

Страница 38: ...filters All replacement filters will use a Mopec BF035 Potassium Permanganate Filter in each slot Install the new filters with the white side down and black mesh up top Close filter door and tighten...

Страница 39: ...ter media is an eye irritant Emergency Treatment Flush eyes with large quantities of water and seek medical attention Filter Disposal Dispose of contaminated filters in accordance with your facility s...

Страница 40: ...facility and operates independently from the Main power switch The reset procedure is the same as section 7 1 3 above 7 2 Stainless Steel Maintenance Cleaning 7 2 1 Disinfecting Stainless steel All st...

Страница 41: ...hem to the stainless steel Always rinse all disinfectants before they dry Decal solutions and fumes are very aggressive and can deposit rust if not cleaned Formalin use has not been shown to cause rus...

Страница 42: ...bing with a paste of soda ash sodium carbonate and water which would be applied with a soft cloth It is best to follow with a warm water rinse 7 3 Mopec Service PLEASE have the following Information a...

Страница 43: ...rt Check connections at the wire whip or power cord and plug connector Disconnect power check circuits harness connections REF 9 2 Elevation Failures My Station does not elevate Station not turned ON...

Страница 44: ...heck in lower skirting for interference Mixing valve OFF Turn mixing valve ON Gate valve for end rinse OFF Turn gate valve ON Water system plugged Check Y Strainers for debris Check for kinked supply...

Страница 45: ...ver Check driver output Replace driver GARBAGE DIPOSAL Garbage Disposal Garburator not working Disposal is jammed turn off facility breaker and remove jam REF 8 2 3 Facility breaker is tripped Reset f...

Страница 46: ...place faulty sensor FORMALIN COLLECTION SYSTEM Formalin collection icon showing on touch screen Formalin collection Jug Carboy is full Empty formalin Jug Carboy Float switch disconnected Plug float sw...

Страница 47: ...is distributed to the Maestro Use a Phillips screwdriver to remove the 10 fasteners It is important to leave 8 inches of clearance in order to access this panel as it houses the main circuit board and...

Страница 48: ...ide of the disposal housing press to reset Access to this button may require removal of the base skirting panels If the disposal will not reset you may need to replace the disposal or check the air li...

Страница 49: ...onnection to the switch has not become dislodged or completely disconnected due to shipping and handling or service in the area The airline is located on the back of the unit behind the sink the foot...

Страница 50: ...Atmospheric Vacuum Breaker equipped faucets Chicago Faucets GN8BVBJKABCP o 8 rigid swing gooseneck spout with atmospheric vacuum breaker Chicago Faucets In line Dual Check valve backflow preventer Us...

Страница 51: ...Installation Service User Manual Maestro series MB1000 MAN rev 1 51 9 Documentation 9 1 Sample Rough in Drawing...

Страница 52: ...Installation Service User Manual Maestro series MB1000 MAN rev 1 52 9 2 Electrical diagrams...

Страница 53: ...Installation Service User Manual Maestro series MB1000 MAN rev 1 53...

Страница 54: ...Installation Service User Manual Maestro series MB1000 MAN rev 1 54...

Страница 55: ...Installation Service User Manual Maestro series MB1000 MAN rev 1 55 9 3 Plumbing diagrams...

Страница 56: ...Installation Service User Manual Maestro series MB1000 MAN rev 1 56...

Страница 57: ...Installation Service User Manual Maestro series MB1000 MAN rev 1 57 9 4 HVAC Ventilation diagram The following is a graphic representation of airflow on an in house ventilated Maestro...

Страница 58: ...bly PP1027 Moen AS 4201 CH Garbage disposal Disposal Air Switch controller PP1028 Moen ARC 4200 Garbage disposal Water Solenoid Assembly 3 8 PP1023 Parker C11123P3 Foot pedal 1 HP disposal Hands Free...

Страница 59: ...24VDC 480W PE0745 Automation Direct PSB24 480 Ventilation Hood Fan FAS PE0750 DigiKey 08025SA 24N ET 00 ND Ventilation Worksurface GFCI Power Outlet 20a PE0510 Leviton 034 N7899 HGG Power Hood 10 1 2...

Страница 60: ...ly the branch of medicine that deals with the laboratory examination of samples of body tissue for diagnostic or forensic purposes Decal Refers to decalcification agents used as a technique for removi...