P
ar
t
2: C
omman
d
s
Moog Animatics SmartMotor™ Developer's Guide, Rev. L
Page 705 of 909
EXAMPLE:
(Shows use of SLD, SLE, SLM, SLN and SLP)
EIGN
(
W
,0)
'Make all onboard I/O inputs
ZS
'Clear errors
SLD
'Disable software limits
O
=0
'Zero the encoder position CTR(0)
SLM
(1)
'SLM(1) will make a soft limit trigger the flag AND
'cause a fault
'SLM(0) will make a soft limit trigger the flag AND
'will NOT cause a fault
SLN
=-8000
'Set the negative software limit to -8000 encoder counts
SLP
=8000
'Set the positive software limit to 8000 encoder counts
SLE
'Enable software limits
MP
'Set the SmartMotor to position mode
ADT
=100
'Set a value for accel/decel
VT
=20000
'Set a value for velocity target
PT
=7000
G TWAIT
'Move to absolute position 7000 (no fault)
PT
=-7000
G TWAIT
'Move to absolute position -7000 (no fault)
PT
=9000
G TWAIT
'Move to absolute position 9000
'The motor will fault at position 8000 and set
'the following bits
'Bo(Motor is off) in Status Word 0
'Brs(Historical positive S/W limit) in Status Word 1
WAIT
=2000
'Wait two seconds
ZS
'Clear errors
PT
=0
G TWAIT
'Move to absolute position 0 (no fault)
END
RELATED COMMANDS:
Software Limits, Disable (see page 702)
R
Software Limit Mode (see page 710)
R
Software Limit, Negative (see page 712)
R
Software Limit, Positive (see page 714)
Part 2: Commands: SLE