Moog Animatics SmartMotor™ Developer's Guide, Rev. L
Page 514 of 909
LEN1
Length of Character Count in Communications Port 1
APPLICATION:
Communications control
DESCRIPTION:
Number of characters in channel 1 receive buffer
EXECUTION:
Immediate
CONDITIONAL TO:
Communications channel 1 must be open in data mode-
LIMITATIONS:
Maximum buffer length is 31 characters
READ/REPORT:
RLEN1
WRITE:
Read only
LANGUAGE ACCESS:
Formulas and conditional testing
UNITS:
Number of available characters
RANGE OF VALUES:
0 to 31
TYPICAL VALUES:
0 to 31
DEFAULT VALUE:
0
FIRMWARE VERSION:
5.0.x, 5.16.x or 5.32.x series only
COMBITRONIC:
N/A
DETAILED DESCRIPTION:
The LEN1 command checks the receive buffer of serial communications channel 1 and returns
the number of characters that are waiting to be processed. Testing the value of LEN1 is a good
way to see if there is a character waiting for retrieval with GETCHR1 command (see the
following example).
NOTE:
M-style motors do not have the second communications port (COM 1)
needed to support the LEN1 and GETCHR1 commands.
EXAMPLE:
i=0
IF
LEN1
>0
'Any data received?
GOSUB5
'If so, process data
ENDIF
END
C5
ab[i]=
GETCHR1
'Read and store in data
'Process incoming data
i=i+1
'Maintain reference index
RETURN
From the above example, "i" will be equal to LEN1.