P
ar
t
2: C
omman
d
s
Moog Animatics SmartMotor™ Developer's Guide, Rev. L
Page 308 of 909
The Bj(1) bit is reset by any of the following:
l
Power reset
l
Z command (total reset of software)
l
Z(1,7) command
l
ZS command
EXAMPLE:
(simple homing)
MV
'Set buffered velocity mode
ADT=
10
'Set buffered accel/decel
VT=
-4000
'Set low buffered maximum velocity
i
=0
'A flag to know if any index was found
ZS G
'Start slow motion profile
Aj
(0)
'Clear and arm index capture
WHILE
Bm
==0
'Travel until negative limit reached
IF
Bj
(0)==1
PT=J
(0)
'Save this target
Aj
(0)
'Clear and arm index capture
i
=1
'Set flag to indicate index was found
ENDIF
LOOP
X
'Decelerate to a stop
IF
i
==0
'Index not seen, must have started close to limit
VT=
4000
'Set low buffered maximum velocity
Aj
(0)
'Clear and arm index capture
ZS G
WHILE
Bj
(0)==0
'Travel positive until index reached
LOOP
PT=J
(0)
'Go back to index
ENDIF
MP ZS G
'Start motion
TWAIT
'Wait till end of trajectory
O
=0
'Set origin at index
Index used as High Speed Position Capture:
When enabled through EIRI, the Bj(0) flag is set to 1 when a falling edge is seen at I/O pin 6.
As a result, I/O pin 6 can be used to capture position for high-speed registration applications.