P
ar
t
2: C
omman
d
s
Moog Animatics SmartMotor™ Developer's Guide, Rev. L
Page 602 of 909
Allowed Values for D-style Motors
Type
Chnl
Parity
Baud
Stop
bits
Data
bits
Mode
Timeout
(optional)
RS2
0
E, O, N
100, 300, 600, 1200,
2400, 4800, 9600, 19200,
38400, 57600, 115200
1, 2
8
C, D
Relevant in C
(command)
mode
RS4
0, 1
E, O, N
100, 300, 600, 1200,
2400, 4800, 9600, 19200,
38400, 57600, 115200
1, 2
8
C, D
Relevant in C
(command)
mode
MB4
1
E, O, N
100, 300, 600, 1200,
2400, 4800, 9600, 19200,
38400, 57600, 115200
1, 2
8
D
N/A
DMX
1
N
250000
2
8
D
N/A
IIC
1
N/A
60000 to
1000000
N/A
N/A
D
N/A
Parity: O=odd, E=even, N=none; Mode: C=command, D=data
NOTE:
For the D-style motor, opening channel 0 as an RS-485 port dedicates I/O
pin 6 to the RS-485 control function. This is required for use with Moog Animatics
RS-232 to RS-485 converters like the RS485 and RS485-ISO.
Allowed Values for M-style Motors
Type
Chnl
Parity
Baud
Stop
bits
Data
bits
Mode
Timeout
(optional)
RS4
0
E, O, N
100, 300, 600, 1200, 2400,
4800, 9600, 19200, 38400,
57600, 115200
1, 2
8
C, D
Relevant in C
(command)
mode
MB4
0
E, O, N
100, 300, 600, 1200, 2400,
4800, 9600, 19200, 38400,
57600, 115200
1, 2
8
D
N/A
DMX
0
N
250000
2
8
D
N/A
Parity: O=odd, E=even, N=none; Mode: C=command, D=data
EXAMPLE:
(Shows use of ECHO_OFF1 and OCHN)
EIGN
(W,0)
'Make all onboard I/O inputs
ZS
'Clear errors
OCHN
(RS4,1,N,9600,1,8,C)
'Open aux communications channel
ECHO_OFF1
'Turn echo off for aux communications channel
END
RELATED COMMANDS:
Close Communications Channel (RS-232 or RS-485) (see page 360)
R
Communications Error Flag (see page 361)
Part 2: Commands: OCHN(...)