P
ar
t
2: C
omman
d
s
Moog Animatics SmartMotor™ Developer's Guide, Rev. L
Page 492 of 909
EXAMPLE:
(Routine pulses output on a given position)
EIGN
(W,0)
'Disable limits
ZS
'Clear faults
ITR
(0,4,0,0,1)
'ITR(int#,sw,bit,state,lbl)
ITRE
'Enable all interrupts
EITR
(0)
'Enable interrupt 0
OUT
(1)=1
'Set I(0)/O B to output, high
ADT
=100
'Set maximum accel/decel
VT
=100000
'Set maximum velocity
MP
'Set Position mode
'****Main Program Body****
WHILE
1>0
O
=0
'Reset origin for move
PT
=40000
'Set final position
G
'Start motion
WHILE
PA<20000
'Loop while motion continues
LOOP
'Wait for desired position to pass
OUT
(1)=0
'Set output low
TMR
(0,400)
'Use timer 0 for pulse width
TWAIT
WAIT
=1000
'Wait 1 second
LOOP
END
'****Interrupt Subroutine****
C1
OUT
(1)=1
'Set output high again
RETURNI
RELATED COMMANDS:
Disable Interrupts (see page 388)
E-Configure Input as Sync Master (see page 416)
Enable Interrupts (see page 417)
End Program Code Execution (see page 431)
ITR(Int#,StatusWord,Bit#,BitState,Label#)
Interrupt Setup (see page 486)
Interrupt Disable, Global (see page 489)
Pause Program Execution (see page 617)
Resume Program Execution (see page 672)
Return Interrupt (see page 676)
Part 2: Commands: ITRE
Содержание SmartMotor
Страница 1: ...Developer s Guide Class 5 Later SmartMotor Technology with TM ...
Страница 909: ...PN SC80100003 002 Rev L ...