P
ar
t
2: C
omman
d
s
Moog Animatics SmartMotor™ Developer's Guide, Rev. L
Page 527 of 909
MCDIV=formula
Mode Cam Divisor
APPLICATION:
Motion control
DESCRIPTION:
Cam mode ratio divisor
EXECUTION:
Buffered at start of cam motion and at restarts due to MFSLEW
length
CONDITIONAL TO:
Cam mode active
LIMITATIONS:
N/A
READ/REPORT:
RMCDIV
WRITE:
Read/write
LANGUAGE ACCESS:
Assignment, formulas and conditional testing
UNITS:
N/A
RANGE OF VALUES:
-32767 to -1 and 1 to 32767 (0 excluded)
TYPICAL VALUES:
-32767 to -1 and 1 to 32767 (0 excluded)
DEFAULT VALUE:
1
FIRMWARE VERSION:
5.x and later
COMBITRONIC:
MCDIV:3=1234
where ":3" is the motor address — use the actual address or a
variable
DETAILED DESCRIPTION:
The MCDIV command provides the Cam mode ratio divisor. It works in combination with the
MCMUL command, which provides the Cam mode ratio multiplier. For usage details, see
MCMUL=formula on page 530.
NOTE:
MCDIV cannot be set to 0.
EXAMPLE:
For examples, see MCMUL=formula on page 530.
RELATED COMMANDS:
Mode Cam (Electronic Camming) (see page 524)
R
Mode Cam Multiplier (see page 530)
Mode Follow, Stall-Dwell-Continue (see page 573)
Mode Follow Slew (see page 575)
Part 2: Commands: MCDIV=formula