Programmable Multi-Axis Servo Drive Power Supply Unit Operation Manual
ID no.: CA97556-001 Date: 03/2015
moog
15
Mechanical installation
1) Power cable
2) Main switch
3) Fuses
4) Mains filter Unfiltered cables must be routed at a distance of least 200 mm (7.87 in) from the mains input side of the filter,
to prevent interference.
5) Circuit-breaker
6) Mains contactor
7) Input choke with connected capacitor
8) Step-up choke
9) Power Supply Unit
10) Multi-Axis Servo Drive
11) DC power supply via DC link cable
12) Braking resistor
13) Motor cables
14) Control
Figure 2.1 Example: Cabinet layout
NOTE:
Arrange the control section separately from the power section, so as to avoid
electromagnetic interference mechanisms.
Control and signal cables and shields have been omitted for the sake of clarity.
y
Use metallically bright backing plates.
y
The rear panel of the servo drive must have good contact with the switch
cabinet earth. The contact area must be metallically bright, in order to make a
good earth connection to the cabinet earth. There must be no air gap between
the rear panel of the servo drive and the switch cabinet wall.
y
The choke bases must have good contact with the cabinet earth. The contact
area must be metallically bright, in order to make a good earth connection to
the cabinet earth.
1
ON
0
OFF
0
PW
R
LOCK
CF
Pow
er
Rese
t
RJ-45/Lin
e
RS 23
2
COM
Data
Statu
s
< 200 mm
< 20
1
7
8
6
5
4
3
2
12
9
10
10
10
10
11
14
13