Programmable Multi-Axis Servo Drive Power Supply Unit Operation Manual
ID no.: CA97556-001 Date: 03/2015
moog
46
Electrical installation
Value
Value name
Description
12
OUTPUT_FS_I_LIM_ACTIV
No function
13
OUTPUT_FS_ENMO
No function
14
OUTPUT_FS_PLC
No function
15
OUTPUT_FS_WARN
General warning
16
OUTPUT_FS_WUV
Warning: undervoltage in DC link (defined in
P-0730
[0,1])
17
OUTPUT_FS_WOV
Warning: overvoltage in DC link (defined in
P-0730
[2,3])
18
OUTPUT_FS_WIIT
Warning: I2t-power stage protection threshold reached
(defined in
P-0730
[6,7])
19
OUTPUT_FS_WOT_PTC
Warning: KTY sensor of step-up choke (defined in
P-0730
[12,13])
20
OUTPUT_FS_WOTI
Warning: heat sink temperature of Power Supply Unit
(defined in
P-0730
[08,9])
21
OUTPUT_FS_WOTD
Warning: internal temperature in Power Supply Unit (defined
in
P-0730
[10,11])
22
OUTPUT_FS_WLIS
Warning: apparent current limit value exceeded (defined in
P-0730
[4,5])
23
OUTPUT_FS_WLVOLT
Warning: DC link voltage limit value exceeded (defined in
P-0730
[14,15])
24
OUTPUT_FS_COM_1MS
Setting outputs via COM Option in 1 ms cycle
25
OUTPUT_FS_COM_NC
Setting outputs via COM Option in NC cycle
26
OUTPUT_FS_SH_S
No function
27
OUTPUT_FS_BC_FAIL
Brake chopper fail error (Error = LOW)
28
OUTPUT_FS_WLPOW
Effective power limit exceeded (defined in
P-0730
[16,17])
29
OUTPUT_FS_GRID_OK
Mains OK (frequency AND voltage within tolerance window
= high)
Table 3.8 Selectable functions of digital outputs OSD00 to OSD02
3.9
Functions of the digital inputs
The following functions can be selected for digital inputs ISD00 to ISD06:
Value
Value name
Description
0
MPRO_INPUT_FS_OFF
No function
1
MPRO_INPUT_FS_START
Start loop control
2
MPRO_INPUT_FS_E_EXT
External error on another device
3
MPRO_INPUT_FS_WARN
External warning on another device
4
MPRO_INPUT_FS_RSERR
Reset an error message
Table 3.7 Selectable functions of digital inputs ISD00 to OSD06
3.10 Functions of the digital outputs
The following functions can be selected for digital outputs OSD00 to OSD02:
Value
Value name
Description
0
OUTPUT_FS_OFF
No function
1
OUTPUT_FS_ERR
General error
2
OUTPUT_FS_ACTIV
Control in function
3
OUTPUT_FS_S_RDY
Device initialised
4
OUTPUT_FS_PRECHARGE_RDY
Device precharged
5
OUTPUT_FS_C_RDY
Device ready (DC link voltage present)
6
OUTPUT_FS_REF
DC link voltage reference (setpoint) reached
7
OUTPUT_FS_E_FLW
No function
8
OUTPUT_FS_LIMIT
DC link voltage reference limitation active (the voltage is
outside the defined range.)
9
OUTPUT_FS_UDC_GT_UDCX
Actual DC link voltage higher than defined in parameter
P-0740
Voltage threshold
10
OUTPUT_FS_P_LIM_ACTIV
No function
11
OUTPUT_FS_UDC_LIM_ACTIV
DC link voltage reference limitation active (the voltage is
outside the defined range.)