Programmable Multi-Axis Servo Drive Power Supply Unit Operation Manual
ID no.: CA97556-001 Date: 03/2015
moog
72
Appendix
A.8 Technical data of input choke
For size
Size 5
Size 6A
For model
G396-026
G396-050
G396-075
G396-110
Rated alternating
current
3 x 40 A
3 x 76 A
3 x 115 A
3 x 170 A
System voltage
3 x 400 VAC ... 3 x 480 VAC
Power loss at 100 %
ED
120 W
144 W
180 W
174 W
Frequency
50/60 Hz
Protection
IP00, cabinet installation required
Fitting position
Condensers with liquid or viscous fillings must be installed upright, with the terminals
up.
Power connections
Cable connection
capacity (flexible
without/with
ferrule)
1.5 ... 16 mm
2
(0.0023 ... 0.025 in
2
)
1.5 ... 16 mm
2
(0.0023 ... 0.025 in
2
)
(AWG 18...AWG 6)
2.5 ... 35 mm
2
(0.004 ... 0.05 in
2
)
2.5 ... 35 mm
2
(0.004 ... 0.05 in
2
)
(AWG 12...AWG 0)
16 ...120 mm
2
(0.025 ... 0.19 in
2
)
16 ... 95 mm
2
(0.025 ... 0.15 in
2
)
(AWG 4...kcmil 250)
Tightening torque
1.5 ... 2.4 Nm
(13.2 ... 21.2 lb-in)
4 ... 5 Nm (35.4 ... 44.2 lb-in)
12 ... 20 Nm
(106.2 ... 177 lb-in)
Table A.15 Technical data of input choke
A.7 Technical data of step-up choke
For size
Size 5
Size 6A
For model
G396-026
G396-050
G396-075
G396-110
Rated alternating
current
3 x 40 A
3 x 76 A
3 x 115 A
3 x 170 A
System voltage
3 x 400 VAC ... 3 x 480 VAC
Rated for effective
power(step-up mode
650 V
DC
/770 V
DC
)
26 kW
50 kW
75 kW
110 kW
Power loss at 100 %
ED
225 W
440 W
400 W
930 W
Frequency
50/60 Hz
Protection
IP00, cabinet installation required
Temperature sensor
KTY84-130
Power connections
Cable connection
capacity (flexible
without/with ferrule)
1.5 ... 16 mm
2
(0.0023 ... 0.025 in
2
)
1.5 ... 16 mm
2
(0.0023 ... 0.025 in
2
)
(AWG 18...AWG 6)
2.5 ... 35 mm
2
(0.004 ... 0.05 in
2
)
2.5 ... 35 mm
2
(0.004 ... 0.05 in
2
)
(AWG 12...AWG 0)
16 ...120 mm
2
(0.025 ... 0.19 in
2
)
16 ... 95 mm
2
(0.025 ... 0.15 in
2
)
(AWG 4...
kcmil 250)
Tightening torque
1.5 ... 2.4 Nm
(13.2 ... 21.2 lb-in)
4 ... 5 Nm (35.4 ... 44.2 lb-in)
12 ... 20 Nm
(106.2 ... 177 lb-in)
KTY sensor
Cable connection
capacity (flexible,
with ferrule)
0.5 ... 2.5 mm
2
(0.0008 ... 0.004 in
2
)
(AWG 30...AWG 12)
Tightening torque
0.4 ... 0.8 Nm (3.5 ... 7.0 lb-in)
Table A.14 Technical data of step-up choke
Содержание G396-026
Страница 12: ...Programmable Multi Axis Servo Drive Power Supply Unit Operation Manual ID no CA97556 001 Date 03 2015 moog 12...
Страница 83: ...Programmable Multi Axis Servo Drive Power Supply Unit Operation Manual ID no CA97556 001 Date 03 2015 moog 81...
Страница 84: ...Programmable Multi Axis Servo Drive Power Supply Unit Operation Manual ID no CA97556 001 Date 03 2015 moog 82...