35
SERVICE
Problem Probable Cause Corrective Action
Problems Related to the Gas and/or Electrical Current
The main indicator of a gas or electrical circuit problem is an entire battery of fryers fails to
light. Verify that the quick disconnect hose is properly connected, the fryer is plugged in, the
main gas supply valve is open.
Problems Related to the Electrical Circuits
If gas is being supplied to the fryer, the next most likely cause of ignition failure is a problem in
the millivolt circuit of the pilot system. If the fryer is equipped with a Filter Magic II fil-tration
system, first verify that the drain valve is fully closed. (The valve is attached to a microswitch
that must be closed for power to reach the gas valve. Often, although the valve handle appears
to be in the closed position, the microswitch is still
The drain linkage is attached to
a microswitch, which prevents the fryer from operating if the
drain valve is open