![MONTAGUE Legend RD18 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/montague/legend-rd18/legend-rd18_instruction-manual_1829526031.webp)
29
SERVICE
Problem Probable Cause Corrective Action
HIGH LIMIT CONTROL
The fryer is equipped with a high limit control which is located behind the front panel.
The function of the high limit control is to shut down the unit in the event of a thermostat failure
which would allow the cooking oil to be overheated. The operating limit of this safety control is
between 440°F to 460°F.
In the event of a high limit “shut down”, the entire system will be put out of operation and
relighting the pilot will be required (refer to lighting instructions).
DO NOT attempt to relight the pilot until the oil temperature has lowered to approxi-
mately 350°F.
Replacing the High-Limit Thermostat
1. Drain fryer and turn gas off.
2. Disconnect wires at the gas valve.
3. Use a slotted socket to unscrew the thermostat from the
frypot.
4. Apply a small amount of Loctite PST56765 compound to the threads of the new thermostat.
5. Install the new high-limit thermostat.
CAUTION
The operating thermostat must be calibrated after installation is complete. Refer to
calibration instructions.
The high-limit thermostat is below the
thermostat dial on the RF40.
Содержание Legend RD18
Страница 42: ...40 SERVICE...