33
SERVICE
Problem Probable Cause Corrective Action
3. To replace the complete pilot assembly:
a.
Disconnect the pilot tubing from the bottom of the pilot assembly.
b. Remove the screw from the pilot-mounting bracket to release the pilot assembly.
c. Disconnect the thermopile fitting from the gas valve pilot coil.
d. Reverse steps a through c to install the replacement pilot assembly.
4. Reinstall the burner assembly by reversing steps 1-8 of
Replacing Burner Ceramic Targets.
Replacing the Frypot
1. Drain the frypot.
2. Remove all accessories (e.g., frypot covers,
basket lift arms, etc.) and hi-back from the fryer.
3. Disconnect the fryer from gas supplies.
4. Remove the screws from the
control panel and lift it from the fryer(s).
5. Remove nuts from the left and right side
underneath the top front edges.
6. Remove tubing from gas train.
7. Pull worksurface and frypot assembly
forward to disengage from rear hold-downs.
8. Lift frypot complete with burner, gas valve, flue, drain valve and combustion chamber from
the fryer cabinet. After lifting the frypot partially out of the cabinet, tilt the front downward to
allow the drain valve to pas by the cabinet top and front crossbar.
9. Remove the drain valve, hi-limit, and operating thermostat and transfer them to the replace-
ment frypot. Before installing thermostats and drain valve on the replacement frypot, clean
threads and apply Loctite PST56765 thread sealant to the threads.
10. Reverse the previous procedures to install the new frypot.
Gas line for pilot.